Chromatographic Techniques for Assessment of Bisoprolol Fumarate and Perindopril Arginine in Solid Formulations Under Various Stress Conditions and Application to Six Sigma, Content Uniformity, and Comparative Dissolution Approaches.

Ammena Y. Binsaleh,A. Omran,Manal A. Almalki,M. Mohamed,Osama A. Mahmoud
DOI: https://doi.org/10.1093/jaoacint/qsad077
2023-06-21
Journal of AOAC International
Abstract:BACKGROUND Antihypertensive bisoprolol fumarate and perindopril arginine were simultaneously determined in their pure, bulk, and combined tablet dosage form. OBJECTIVE This study develops a novel, reproducible, and accurate RP-HPLC and RP-UPLC with photodiode array detection techniques, which were then applied to in vitro dissolving studies. METHOD The first RP-HPLC method relied on isocratic elution using a mobile phase consisting of methanol and 0.05M phosphate buffer pH 2.6 (50:50 v/v), and separation was done by a stationary phase Thermo Hypersil C8 column (150 mm × 4.6 mm, 5 μm). Ion-pair UPLC was the second method. An acceptable resolution was achieved using RP-C18 chromatographic column Agilent Eclipse (100 ×2.1 mm, 1.7 μm) with a mobile phase containing 0.005 M sodium 1-heptane sulfonate and 1 mL of triethylamine in the aqueous phase at pH 2.0 and acetonitrile (65:35 v/v). RP-HPLC was equipped with a 1.0 mL/min flow rate, while UPLC had 0.5 mL/min, and the two methods were detected at 210 nm. RESULTS Bisoprolol fumarate and perindopril arginine were linear for RP-HPLC and RP-UPLC at 0.5-15 and 0.5-40 μg/mL, respectively. RP-HPLC LODs were 0.16 μg/mL and 0.12 μg/mL, and LOQs were 0.47 and 0.37 μg/mL. Bisoprolol fumarate and Perindopril Arginine had RP-UPLC LODs of 0.22 and 0.10 μg/mL, respectively, and LOQs of 0.68 and 0.31 μg/mL. As a result, the approach has been effectively applied to in vitro dissolution testing for drugs in the generic and reference products, showing that the two products are comparable. The six sigma approach was implemented to compare the recommended and USP procedures, which both exhibited Cpk >1.33. A content uniformity test demonstrated that the drugs in their dosage form met the acceptance limit (85-115%). The degradation products were reliably distinguished from pure drugs for a range of retention times. CONCLUSION In their commercial drug product, these would be useful in quality control laboratories for concurrent testing, content uniformity, and in vitro dissolution investigations of bisoprolol fumarate and Perindopril Arginine. The methods were successfully validated per ICH guidelines. HIGHLIGHTS This study is innovative since it is the first to establish and validate specific and reproducible UPLC and HPLC methods for the concurrent quantitative of the studied drugs in their binary mixture and application to lean six sigma, content uniformity, and comparative dissolution approaches.
Chemistry,Medicine
What problem does this paper attempt to address?