Robust modelling of arterial blood pressure reconstruction from photoplethysmography

Jiating Pan,Lishi Liang,Yongbo Liang,Qunfeng Tang,Zhencheng Chen,Jianming Zhu
DOI: https://doi.org/10.1038/s41598-024-82026-1
IF: 4.6
2024-12-06
Scientific Reports
Abstract:Blood pressure is a crucial indicator of cardiovascular disease, and arterial blood pressure (ABP) waveforms contain information that reflects the cardiovascular status. We propose a novel deep-learning method that converts photoplethysmogram (PPG) signals into ABP waveforms. We used -Net as a feature extractor and designed a Bi-block to capture individualised time information in encoder feature extraction. We further enhanced the prediction accuracy of the ABP waveforms by applying a combined loss function to each layer of deep supervision. We also propose a total error index (TEI) to measure overall performance. Furthermore, we extended our method from the UCI dataset to the VitalDB dataset, achieving mean absolute error ± standard deviation (MAE ± STD) values of 2.48 ± 1.95, 1.42 ± 1.42, and 1.48 ± 1.36 mmHg for systolic blood pressure (SBP), diastolic blood pressure (DBP), and mean arterial pressure (MAP) in UCI dataset, and 2.16 ± 1.53, 1.12 ± 0.59, and 1.35 ± 0.84 mmHg in VitalDB dataset, respectively. The mean ± STD values of the TEI index are 0.29 ± 0.10 in UCI dataset and 0.29 ± 0.15 in VitalDB dataset. These results demonstrate the superiority of the proposed method over existing methods and its robustness to different sampling frequencies and devices.
multidisciplinary sciences
What problem does this paper attempt to address?