Long Term Outcomes of the Gore Excluder Low Permeability Endoprosthesis for the Treatment of Infrarenal Aortic Aneurysms

Stefan P M Smorenburg,Jorg L de Bruin,Clark J Zeebregts,Michel M P J Reijnen,Hence J M Verhagen,Jan M M Heyligers,Stefan P.M. Smorenburg,Jorg L. de Bruin,Clark J. Zeebregts,Michel M.P.J. Reijnen,Hence J.M. Verhagen,Jan M.M. Heyligers
DOI: https://doi.org/10.1016/j.ejvs.2024.03.028
IF: 6.427
2024-03-28
European Journal of Vascular and Endovascular Surgery
Abstract:Objective This study evaluated the long term outcomes of endovascular aneurysm repair using the Gore Excluder Low Permeability (LP) endoprosthesis across high volume Dutch hospitals. Methods A retrospective analysis was conducted of patients treated with the Excluder LP for infrarenal abdominal aortic aneurysm (AAA) in four hospitals between 2004 – 2017. Primary outcomes were overall survival, freedom from re-interventions (overall, inside/outside instructions for use, IFU), and AAA sac dynamics: growth (> 5 mm), stabilisation, and regression (< 5 mm). Secondary outcomes were technical success (device deployment), procedural parameters, and re-interventions. Follow up visits were extracted from patient files, with imaging assessed for complications and AAA diameter. Results A total of 514 patients were enrolled, with a median (IQR) follow up of 5.0 (2.9, 6.9) years. Survival rates were 94.0% at 1 year, 73.0% at 5 years, and 37.0% at 10 years of follow up, with freedom from re-interventions of 89.0%, 79.0%, and 71.0%, respectively. Treatment outside IFU was 37.9%, leading to significantly more re-interventions over 10 years compared with inside IFU (36.0% vs. 25.0%, respectively; p = .044). The aneurysm sac regressed by 53.5% at 1 year, 65.8% at 5 years, and 77.8% at 10 years, and grew by 9.8%, 14.3%, and 22.2%, respectively. Patients with 1 year sac growth had significantly worse survival ( p = .047). Seven patients (1.4%) had a ruptured aneurysm during follow up. Over 15 years, endoleak type 1a occurred in 5.3%, type 1b in 3.1%, type 3 in 1.9%, type 4 in 0.2%, and type 2 in 35.6% of patients. Conclusion This multicentre study of real-world endovascular aneurysm repair data utilising the Gore Excluder LP endoprosthesis demonstrated robust long term survival and re-intervention rates, despite 37.9% of patients being treated outside IFU, with type 4 endoleak being rare. Treatment outside IFU significantly increased re-intervention rates and 1 year sac growth was associated with statistically significantly worse survival.
surgery,peripheral vascular disease
What problem does this paper attempt to address?