Impact of Synchronous Condenser on Sub/Super-Synchronous Oscillations in Wind Farms

Yuzhi Wang,Liang Wang,Qirong Jiang
DOI: https://doi.org/10.1109/tpwrd.2020.3019481
IF: 4.825
2021-08-01
IEEE Transactions on Power Delivery
Abstract:Sub/Super-synchronous oscillations have occurred in wind farms consisting of doubly-fed induction generators (DFIGs) or permanent magnet synchronous generators (PMSGs). This paper investigates the impact of synchronous condenser (SC) on sub/super-synchronous oscillations in wind farms with different types of generator and compares it with STATCOM. Impedance model is adopted in this paper to explain the mechanism of oscillations in wind farms and its mitigation using SC. Compared to STATCOM, SC is more effective in oscillation mitigations of the two types of wind farms. Eigenvalue analysis and time domain simulations in PSCAD/EMTDC are used to check the influence on sub/super-synchronous oscillations from different parameters of SC, such as its capacity, leakage reactance and inertia constant. The results indicate that SC would improve the system stability while a larger capacity will induce a greater improvement. A smaller leakage reactance of SC also benefits the mitigation of oscillations while its inertia constant can hardly influence system stability.
engineering, electrical & electronic
What problem does this paper attempt to address?
The problem that this paper attempts to solve is the influence of synchronous condensers (SC) on sub/super - synchronous oscillations in wind farms based on doubly - fed induction generators (DFIG) and permanent - magnet synchronous generators (PMSG). Specifically, the paper explores the oscillation suppression effects of SC in different types of wind farms and compares it with static synchronous compensators (STATCOM). The impedance model is used to explain the oscillation mechanisms in wind farms and the methods of suppressing them using SC. In addition, the paper also uses eigenvalue analysis and time - domain simulation in PSCAD/EMTDC to examine the effects of different parameters of SC (such as capacity, leakage inductance and inertia constant) on sub/super - synchronous oscillations. The main research contents of the paper include: 1. **Problem Background**: The manifestations and causes of sub/super - synchronous oscillations in traditional power systems and modern wind power generation systems are introduced. In particular, the oscillation problems caused by the application of DFIG and PMSG in wind farms. 2. **Research Method**: The impedance model is used to analyze the oscillation mechanism, and the oscillation suppression effect of SC is verified by eigenvalue analysis and time - domain simulation. 3. **Experimental Results**: The results show that SC is more effective in oscillation suppression than STATCOM, especially for DFIG and PMSG - type wind farms. The larger the capacity of SC, the more significant the improvement in system stability; a smaller leakage inductance also helps in oscillation suppression, while the inertia constant has less influence on system stability. 4. **Conclusion**: SC can improve system stability, especially in the sub/super - synchronous oscillation frequency range. The impedance characteristics of SC give it an advantage in suppressing oscillations. Through these studies, the paper provides theoretical basis and technical support for the stable operation of wind farms.