Experimental Study on Suppression of Lithium Iron Phosphate Battery Fires

Liming Yuan,Wei Tang,Richard A. Thomas,John Soles
DOI: https://doi.org/10.1007/s42461-024-00938-y
2024-02-17
Abstract:Lithium-ion battery applications are increasing for battery-powered vehicles because of their high energy density and expected long cycle life. With the development of battery-powered vehicles, fire and explosion hazards associated with lithium-ion batteries are a safety issue that needs to be addressed. Lithium-ion batteries can go through a thermal runaway under different abuse conditions including thermal abuse, mechanical abuse, and electrical abuse, leading to a fire or explosion. The NIOSH Mining program is conducting research to prevent and respond to lithium-ion battery fires for battery electric vehicles in the mining industry. In this study, experiments were conducted to investigate the effectiveness of different suppression systems including dry chemical, class D powder, and water mist for lithium iron phosphate battery pack fires. The effects of activation time and release time of the water mist system on the suppression of lithium-ion battery fires were studied. The results of this study may be helpful for developing strategic firefighting and response plans for battery-powered vehicles used in mining.
mining & mineral processing,metallurgy & metallurgical engineering
What problem does this paper attempt to address?