The force effects of two types of polyethylene terephthalate glyc-olmodified clear aligners immersed in artificial saliva

Biao Xiang,Xingxing Wang,Gang Wu,Yichen Xu,Menghan Wang,Yanjing Yang,Qingyu Wang
DOI: https://doi.org/10.1038/s41598-021-89425-8
IF: 4.6
2021-05-12
Scientific Reports
Abstract:Abstract Numerous factors can influence the force exerted by clear aligners on teeth. This study aimed to investigate the stability of the force delivered by two different material appliances. 90 clear aligners with 2 materials and three different activations were designed and fabricated. Then, a device was employed to measure the force generated by the two types of PET-G material appliances immersed in artificial saliva for 0, 3, 7, 10, 14 days. Scanning electron microscopy was applied to observe the morphologic alterations on the aligner surfaces, respectively. The forces generated by different activation appliance exhibited differently, 0.0 mm < 0.1 mm < 0.2 mm. In addition, increasing the immersion times and the orthodontic force also decreased, but the forces decreased differently. Compared with the forces of conventional PETG appliances with 0.20 mm activation, the modified PETG appliances with the same activation exhibited significantly higher mean force. When comparing the mean force for modified PETG appliances after 10 and 14 days with conventional PETG appliances, the delivery forces exhibited significant differences ( P < 0.05). The force delivered by both materials decreased obviously following artificial saliva immersion, and the force generated by modified aligners exhibited better stability than conventional aligners.
multidisciplinary sciences
What problem does this paper attempt to address?
The paper aims to study the mechanical performance stability of two different materials (traditional polyethylene terephthalate glycol-modified material PETG and modified PETG) for clear aligners after being soaked in artificial saliva. Specifically, the research focuses on the force value changes of these aligners under different activation levels (0.0 mm, 0.1 mm, 0.2 mm) and different soaking times (0 days, 3 days, 7 days, 10 days, 14 days), as well as changes in surface morphology and chemical composition. Through these studies, the authors hope to understand the performance changes of clear aligners in a simulated oral environment, thereby providing more stable and effective material choices for clinical applications. The study found that the aligners made of modified PETG material exhibited more stable force values after being soaked in artificial saliva compared to those made of traditional PETG material. This was especially evident after 10 days and 14 days of soaking, where the aligners made of modified PETG material showed significantly higher average force values. Additionally, scanning electron microscope (SEM) observations revealed that the aligners made of modified PETG material had less surface morphology damage after 14 days of soaking, indicating better durability and stability. These results are of great significance for improving the therapeutic effect and patient comfort of clear aligners.