Abstract:<p>A method based on mirror refection interference and fluorescence emission difference is provided to improve the three-dimensional resolution and <em>SNR</em> in confocal microscopy. Theoretical analysis and experimental results have been performed to verify the effectiveness of the method. Our numerical simulations predict that lateral resolution close to 0.285λ and axial resolution close to 0.205λ are possible for practical confocal microscopy with visible light. Furthermore, the <em>SNR</em> has also been improved. The experimental results of both fluorescent beads and cell microtubules are presented to verify the applicability and effectiveness of our method. The ability to increase the lateral resolution and axial resolution using mirror refection interference and fluorescence emission difference without increasing the laser power is of great importance for imaging fluorescent biological specimens, which cannot tolerate high laser power.</p>
optics
What problem does this paper attempt to address?
The paper aims to address the limitations of lateral and axial resolution in confocal microscopy imaging of fluorescent biological samples, particularly in improving resolution without increasing laser power. Specifically, the study proposes a method based on mirror reflection interference (MRIE) and fluorescence emission difference (FED) to enhance the resolution and signal-to-noise ratio (SNR) of confocal microscopy 3D imaging. The core methods of the study include: 1. **Mirror Reflection Interference Enhancement**: By placing a mirror behind the sample and utilizing the interference effect generated by the mirror reflection to compress the axial size of the point spread function (PSF) of the excitation light, thereby achieving axial resolution improvement. 2. **Fluorescence Emission Difference**: By performing mathematical subtraction on images obtained with different-sized pinholes to remove out-of-focus background light, thereby improving lateral resolution while maintaining or enhancing SNR. Combining these two methods can simultaneously improve both lateral and axial resolution without causing a decrease in SNR due to the use of smaller pinholes. Theoretical simulations and experimental results have both validated the effectiveness of this method, particularly in achieving near 0.285λ lateral resolution and 0.205λ axial resolution when using visible light for actual confocal microscopy imaging. Moreover, for fluorescent biological sample imaging that cannot withstand high laser power, this method of improving resolution without increasing laser power is especially important.