Effect of the Height of a 3D-Printed Model on the Force Transmission and Thickness of Thermoformed Orthodontic Aligners

Omar Ghoraba,Christoph Bourauel,Mostafa Aldesoki,Lamia Singer,Ahmed M. Ismail,Hanaa Elattar,Abdulaziz Alhotan,Tarek M. Elshazly
DOI: https://doi.org/10.3390/ma17123019
IF: 3.4
2024-06-20
Materials
Abstract:This research aims to investigate the influence of model height employed in the deep drawing of orthodontic aligner sheets on force transmission and aligner thickness. Forty aligner sheets (Zendura FLX) were thermoformed over four models of varying heights (15, 20, 25, and 30 mm). Normal contact force generated on the facial surface of the upper right central incisor (Tooth 11) was measured using pressure-sensitive films. Aligner thickness around Tooth 11 was measured at five points. A digital caliper and a micro-computed tomography (μ-CT) were employed for thickness measurements. The normal contact force exhibited an uneven distribution across the facial surface of Tooth 11. Model 15 displayed the highest force (88.9 ± 23.2 N), while Model 30 exhibited the lowest (45.7 ± 15.8 N). The force distribution was more favorable for bodily movement with Model 15. Thickness measurements revealed substantial thinning of the aligner after thermoforming. This thinning was most pronounced at the incisal edge (50% of the original thickness) and least at the gingivo-facial part (85%). Additionally, there was a progressive reduction in aligner thickness with increasing model height, which was most significant on the facial tooth surfaces. We conclude that the thermoplastic aligner sheets undergo substantial thinning during the thermoforming process, which becomes more pronounced as the height of the model increases. As a result, there is a decrease in both overall and localized force transmission, which could lead to increased tipping by the aligner and a diminished ability to achieve bodily movement.
materials science, multidisciplinary,chemistry, physical,physics, applied, condensed matter,metallurgy & metallurgical engineering
What problem does this paper attempt to address?
The problem that this paper attempts to solve is to explore the influence of the height of 3D - printed models on the force transmission and thickness of thermoformed orthodontic appliances. Specifically, the research aims to answer the following questions: 1. **How do 3D - printed models of different heights affect the force distribution of appliances on the tooth surface?** 2. **Will the model height affect the thickness change of appliances during the thermoforming process?** 3. **What are the impacts of these changes on the functions of appliances (such as achieving overall tooth movement or tipping)?** ### Research Background Orthodontic clear appliances have obvious advantages over traditional bracket systems because of their aesthetics and the ability to improve oral hygiene. In addition, they also reduce chair - side time and the number of clinical visits, so they are widely used in the dental market. However, to achieve the best clinical results, multiple factors need to be optimized, including material type, thickness, edge shape, extension, and activation level, etc. ### Research Methods The researchers used 3D - printed models with four different heights (15 mm, 20 mm, 25 mm, and 30 mm) for the experiment. Forty thermoforming experiments were carried out on each model, and the material used was Zendura FLX thermoplastic sheet. The normal contact force on the facial surface of the upper right central incisor (Tooth 11) was measured by pressure - sensitive film, and the thickness of the appliance was measured by digital calipers and micro - computer tomography (µ - CT). ### Main Findings - **Force Transmission**: When the model height was 15 mm, the maximum force (88.9 ± 23.2 N) was generated, while when the height was 30 mm, the minimum force (45.7 ± 15.8 N) was generated. The force distribution was uneven, and some areas bore greater forces. - **Thickness Change**: After thermoforming, the thickness of the appliance decreased significantly, especially in the gingival part (60 - 85% of the original thickness). As the model height increased, the thickness of the appliance gradually decreased, especially on the facial surface of the teeth. ### Conclusion The research concludes that the thermoplastic appliance sheet will experience significant thickness reduction during the thermoforming process, and this reduction becomes more obvious as the model height increases. As a result, the overall and local force transmissions are reduced, which may cause the appliance to tip the teeth more easily and reduce its ability to achieve overall movement. ### Formula Representation The formula for calculating force is as follows: \[ \text{Force} = \text{Pressure} \times \text{Area} \] where the unit of pressure is MPa and the unit of area is mm². ### Keywords Biomechanics; Removable Thermoplastic Appliances; Thermoforming; 3D Printing; Micro - computer Tomography (µ - CT) Through this research, the author hopes to fill the research gap in the existing literature regarding the influence of 3D - printed model height on the performance of thermoformed appliances and provide references for future research.