Wall shear stress measurement using a zero-displacement floating-element balance

M. Aguiar Ferreira,P. Costa,B. Ganapathisubramani
DOI: https://doi.org/10.1007/s00348-024-03785-1
IF: 2.797
2024-04-01
Experiments in Fluids
Abstract:The floating-element (FE) principle, introduced nearly a century ago, remains one of the most versatile direct wall shear stress measurement methods. Yet, its intrinsic sources of systematic error, associated with the flow-exposed gap, off-axis load sensitivity, and calibration, have thus far limited its widespread application. In combination with the lack of standard designs and testing procedures, measurement reliability still hinges heavily on individual judgement and expertise. This paper presents a framework to curb these limitations, whereby the design and operation of a FE balance are leveraged by an analytical model that attempts to capture the behaviour and predict the relative contribution of the systematic sources of error. The design is based on a parallel-shift linkage and a zero-displacement force-feedback system. The FE has a surface area of mm, and measurement sensitivity is adjustable depending on the surface condition and the Reynolds number. It is thus suitable for application in a wide range of low-speed, boundary-layer wind tunnels, small or large scale. Measurements of the skin friction coefficient over a smooth wall show a remarkable agreement with oil-film interferometry, especially for . The discrepancy relative to the empirical Coles–Fernholz relation ( and ) is within %, and the level of uncertainty is below % for a confidence interval of %.
engineering, mechanical,mechanics
What problem does this paper attempt to address?
The main problem that this paper attempts to solve is to improve the reliability and accuracy of floating element (FE) balance in measuring wall - shear stress. Specifically, the paper focuses on the following points: 1. **Reducing systematic errors**: Traditional FE balances have multiple sources of systematic errors, such as errors caused by fluid - exposed gaps, non - axial load sensitivity, calibration errors, etc. These errors limit the wide application of FE balances. The paper proposes a new design framework and analysis model, aiming to capture the behavior of these systematic errors and predict their impact on measurement results, thereby reducing these errors. 2. **Improving the design**: The paper introduces a new FE balance design based on parallel - moving linkages and zero - displacement force - feedback systems. This design can effectively reduce non - axial load sensitivity caused by mechanical structures and errors caused by pressure gradients. At the same time, this design has adjustable measurement sensitivity and is suitable for low - speed boundary - layer wind - tunnel experiments under different surface conditions and Reynolds number ranges. 3. **Improving measurement accuracy**: Through the above - mentioned design and analysis model, the paper shows how to improve the measurement accuracy of FE balances. Experimental results show that the friction coefficient measured on a smooth wall using this method is highly consistent with the results of the oil - film interferometry method, especially in the case of \(Re_\theta > 1.3\times10^4\). In addition, the difference between the measurement results and the empirical Coles - Fernholz relation is within 0.5%, and the uncertainty in the 95% confidence interval is less than 1%. In conclusion, by improving the design and operation methods of FE balances and introducing analysis models to predict and reduce systematic errors, this paper aims to improve the reliability and accuracy of wall - shear - stress measurement. This not only contributes to scientific research but also provides a more reliable tool for practical applications.