Experimental Study on Plugging Behavior of Degradable Diverters in Partially Open Fracture in Temporary Plugging and Diverting Fracturing

Ming Li,Jianchun Guo,Fujian Zhou,Minghui Li,Jiaqi Chen,Hui Liu,Qing Wang,Longqiao Hu
DOI: https://doi.org/10.1021/acsomega.3c00689
IF: 4.1
2023-04-25
ACS Omega
Abstract:Temporary plugging and diverting fracturing technology (TPDF) has been successfully applied to improve reservoir productivity. In real reservoirs, a considerable number of fractures have relatively rapidly decreasing fracture widths and closed ends. However, the plugging behavior of diverters in this typical fracture called the partially open fracture (POF) is still unclear because of the few related studies. This paper aims to investigate the plugging behavior of diverters at the fracture tip....
chemistry, multidisciplinary
What problem does this paper attempt to address?
### What problems does this paper attempt to solve? This paper aims to study the plugging behavior of degradable diverters in partially open fractures (POF). Specifically, the paper focuses on the following aspects: 1. **Plugging mechanism**: Through experimental research on the transport and plugging behavior of diverters in partially open fractures, its plugging mechanism is revealed. 2. **Factors affecting plugging performance**: Analyze the influence of different diverter formulations (such as the ratio of fiber and particle, particle size, etc.) and fracture types (partially open fractures and fully open fractures) on the plugging effect. 3. **Guidance for practical applications**: Provide experimental and theoretical basis for the application of temporary plugging and diverting fracturing (TPDF) in tight sandstone reservoirs, and optimize the diverter formulation to improve the plugging effect. #### Background and significance With the increase in global oil and gas consumption, the development of deep - tight reservoirs (with natural fractures and severe heterogeneity) has become increasingly important. However, these reservoirs have poor physical properties, and the traditional hydraulic fracturing technology has a poor effect. For this reason, researchers have proposed the temporary plugging and diverting fracturing technology (TPDF). By using degradable diverters to plug the stimulated area, the injected fluid is forced to enter the under - stimulated area, thus connecting natural fractures and resources, and finally increasing the reservoir production. Although there has been a large amount of research on the plugging behavior of diverters in open fractures, there is less research on the plugging behavior in partially open fractures (especially at the fracture tip). Therefore, this study fills this gap in the field and provides important insights into the plugging behavior of diverters in partially open fractures. ### Main research contents 1. **Experimental design**: - Use 3D printing technology to replicate the partially open fracture model and describe its morphological characteristics based on the scanning data. - Conduct a series of plugging experiments, monitor the transport behavior of diverters in partially open fractures, and study the influence of different diverter formulations and fracture types on the plugging effect. 2. **Experimental results**: - In partially open fractures, when using a combination of fiber and particle, a higher pressure distribution appears at the fracture tip, which is conducive to the transportation of diverters to the tip and the formation of plugging. - Small changes in particle size and concentration have a significant impact on the plugging performance. It is recommended to use a combination of fiber and particle with multiple particle sizes (the maximum is not more than half of the fracture width) to obtain a better plugging effect. - For partially open fractures with widths of 1 mm, 2 mm, and 4 mm respectively, the recommended diverter formulations are: - 1 wt% fiber + 1 wt% 0.15 mm particle - 1 wt% fiber + 1 wt% 0.15 mm particle + 1 wt% 1 mm particle - 1 wt% fiber + 1 wt% 0.15 mm particle + 1 wt% 1 mm particle + 1 wt% 2 mm particle 3. **Plugging mechanism**: - Due to the good deformation performance of the fiber, many fibers are attached to the fracture surface and form a plugging area together with the bridging particles. - A large number of small - particle diverters preferentially enter the fracture and fill the fracture tip, and together with the subsequent fibers and particles, form a dense plugging area. - If the fracture is long enough, the fibers will be wound into a ball and capture the subsequent particles, forming a loose plugging area, and finally make the flow channel narrow until it is completely plugged. ### Conclusion This study reveals the plugging mechanism of diverters in partially open fractures through experimental and theoretical analysis, and provides guidance for optimizing the diverter formulation, which is helpful to improve the application effect of temporary plugging and diverting fracturing technology in tight sandstone reservoirs.