Frequency response of the non-polarization-maintaining depolarized sagnac interferometer based on maximum fringe contrast

Mingchen Zhang,Zhuyuan Huang,Zhigang Cai,Fujuan Wang,Jiahui Wang,Jiaoyang Li,Zixin Wang
DOI: https://doi.org/10.1016/j.optcom.2024.130411
IF: 2.4
2024-02-23
Optics Communications
Abstract:The Sagnac Interferometer offers a promising solution to the speckle problem in interferometric detection due to its insensitivity to environmental low-frequency interference, making it well-suited for applications such as laser ultrasonic detection. Control of the polarization state of light is imperative for achieving high sensitivity in optical fiber interferometer and ensuring optimal quiescent operating conditions. This study employed the coherence matrix method to analyze the theory of optimal polarization control in a non-polarization-maintaining depolarized Sagnac Interferometer, encompassing the deduction of the stable π/2 initial phase bias and the maximum fringe contrast of 50% in theory. In experimental observations during PZT simulated large amplitude ultrasound experiments, the fringe contrast reached 48.4%. Furthermore, the system's amplitude-frequency response was evaluated using an electro-optics phase modulator, demonstrating its capability to detect high-frequency signals within 100 MHz These findings provide essential insights into optimizing the Sagnac Interferometer's performance for laser ultrasonic detection and its potential applications in high-frequency signal detection and ultrasonic amplitude measurement.
optics
What problem does this paper attempt to address?