An Alternative Method for Blood Plasma Preparation Prior to Metabonomics Study
Dong Jun,Cai Xiaoming,Zhang Xiuli,Zhao Lili,Wang Yuanyuan,Xue Xingya,Liang Xinmiao
DOI: https://doi.org/10.1016/j.jbiotec.2008.07.114
IF: 3.595
2008-01-01
Journal of Biotechnology
Abstract:Sample preparation for liquid chromatography with mass spectrometric detection is a major task in metabonomics study which significantly impacts assay throughput and data quality. Protein precipitation technology (PPT) is one of the most popular methods for plasma preparation. However, small amount proteins remain in the supernatant, which result in the performance deterioration of chromatographic column and ion suppression in MS detection. The centrifugal ultrafiltration after methanol extraction of whole plasma could be used as an alternative method for blood plasma preparation prior to metabonomics. The Ultra-performance Liquid Chromatography coupled with Q-TOF Mass Spectrometry was used to analyze the prepared sample and the Markerlynx software for processing the raw data. At first, four common using organic solvents (acetonitrile, methanol, ethanol and acetone) were compared in human plasma for protein precipitation to assess method reproducibility and number of reproducible peaks. Methanol has been demonstrated to extract more than 100 metabolites and has the best reproducibility of four organic solvent. The residual protein values pre- and post ultrafiltration after methanol PPT were 4.8 % and 0.5 % of original plasma by using the Bradford assay method. The data also showed that the numbers of peaks before and after ultrafiltration were 4648 and 4150, while the average RSD values for all metabolites were 21.3% and 16.7 %. Most of important, the column pressure was stable after 500 runs, and the sample analysis displayed excellent separation degree. These results showed that methanol protein precipitation followed by centrifugation and then ultrafiltration was an effective, concise, reproducible method, resulting in plasma metabolites containing over 4000 detected compounds peaks. References: [1] Chang, M.S., Ji, Q. Zhang, J., and El-Shourbagy, T.A. 2007. Historical Review of Sample Preparation for Chromatographic Bioanalysis: Pros and Cons. Drug Dev. Res. 68:107–133 [2] Want, E.J., O’Maille, G., Smith, C.A., Brandon, T.R., Uritboonthai, W., Qin, C., Trauger, S.A. and Siuzdak, G. 2006. Solvent-Dependent Metabolite Distribution, Clustering, and Protein Extraction for Serum Profiling with Mass Spectrometry. Anal. Chem. 78: 743-752 [3] Yin, P.Y., Zhao, X.J., Li,Q.R., Wang, J.S., Li, J.S., and Xu, G.W. 2006. Metabonomics Study of Intestinal Fistulas Based on Ultraperformance Liquid Chromatography Coupled with Q-TOF Mass Spectrometry (UPLC/Q-TOF MS). J.Proteome Res. 5: 2135-2143