One-step dispersive solid phase extraction (dSPE) and protein precipitation to streamline high-throughput reversed-phase metabolic phenotyping of blood samples
María Gómez-Romero,Mark David,Elena Chekmeneva,Stephane Camuzeaux,Benjamin Cooper,Ada Yuen,Ravi Mehta,Shiranee Sriskandan,Miguel Reis Ferreira,Olivier Cloarec,Caroline Sands,Goncalo Correia,Zoltan Takats,Matthew Lewis
DOI: https://doi.org/10.26434/chemrxiv-2024-fm1cl
2024-06-18
Abstract:The chemical analysis of blood products (plasma and serum) is commonplace in metabolic phenotyping studies. The diversity of analytes in blood products characterized by varying physico-chemical properties, stability, and solubility presents an analytical challenge when attempting to achieve comprehensive analyte coverage by liquid chromatography mass spectrometry (LC-MS). While reversed-phase chromatography (RPC) of lipid analytes does not suffer from the presence of small molecules eluting mostly early in the chromatogram, the RPC-based analysis of low-molecular-weight metabolites (LMWMs) in minimally processed blood products is hindered by the presence of proteins and lipid species which fail to cleanly elute and negatively impact the assay. Here, we propose a novel application of dispersive solid phase extraction (dSPE) for the one-step single-phase depletion of proteins and lipids from plasma and serum samples without detrimental effect to the composition of LMWMs, overcoming challenges of conventional SPE. Using this approach, we demonstrate in two clinical studies the paired use of C18 RPC LC-MS for LMWM profiling enabled by dSPE and C8 RPC LC-MS for lipid profiling, providing 650+ annotated LMWMs and lipid species in plasma and serum samples.
Chemistry
What problem does this paper attempt to address?
The main problem that this paper attempts to solve is the analytical challenges faced by blood samples (plasma and serum) in metabolic phenotyping studies. Specifically, since blood samples contain a variety of analytes with different physical and chemical properties, such as proteins, lipids and low - molecular - weight metabolites (LMWMs), the presence of these components poses an obstacle to high - performance liquid chromatography - mass spectrometry (LC - MS) analysis. In particular, the presence of proteins and lipids can cause interference in the detection of low - molecular - weight metabolites in reversed - phase chromatography (RPC) analysis. For example, proteins and lipids are difficult to be completely eluted, resulting in increased column pressure and ion suppression, thus affecting the accuracy of the analysis results.
For this reason, the paper proposes a new method based on dispersive solid - phase extraction (dSPE), aiming to simultaneously remove proteins and lipids in one step without negatively affecting the composition of low - molecular - weight metabolites. This method can overcome the limitations of traditional solid - phase extraction (SPE), achieve more efficient sample processing, and is suitable for high - throughput metabolomics studies. Through this method, the authors were able to analyze low - molecular - weight metabolites using C18 reversed - phase chromatography LC - MS and analyze lipids using C8 reversed - phase chromatography LC - MS in two clinical studies respectively, demonstrating the effectiveness and practicality of this method.