Immunoassay for foodborne pathogenic bacteria using magnetic composites Ab@Fe3O4, signal composites Ap@PtNp, and thermometer readings

Shengjun Bu,Kuiyu Wang,Chengyu Wang,Zhongyi Li,Zhuo Hao,Wensen Liu,Jiayu Wan
DOI: https://doi.org/10.1007/s00604-020-04657-1
IF: 5.7
2020-11-28
Microchimica Acta
Abstract:A point-of-care (POC) immunoassay was established for the sensitive and rapid detection of pathogenic <i>Escherichia coli</i> O157:H7, using magnetic Fe<sub>3</sub>O<sub>4</sub> organic-inorganic composites (Ab@Fe<sub>3</sub>O<sub>4</sub>) for immunomagnetic separation, nanozyme platinum nanoparticle (PtNp) organic-inorganic composites (Ap@PtNp) for signal amplification, and thermometer readings. Antibodies and Fe<sub>3</sub>O<sub>4</sub> were incubated in Cu<sup>2+</sup> phosphate buffer to synthesize the magnetic composite Ab@Fe<sub>3</sub>O<sub>4</sub> with antibodies, to specifically capture <i>E. coli</i> O157:H7. Antimicrobial peptides and PtNp were incubated in Cu<sup>2+</sup> phosphate buffer to synthesize the signal composites Ap@PtNp with antimicrobial peptides (magainin I), recognizing and labeling <i>E. coli</i> O157:H7. In the presence of <i>E. coli</i> O157:H7, magnetic microcomposites targeted bacteria and signal microcomposites to form the sandwich structure: Ab@Fe<sub>3</sub>O<sub>4</sub>-bacteria-Ap@PtNp for magnetic separation. Ap@PtNp of signal composites catalyzed H<sub>2</sub>O<sub>2</sub> to generate thermo-signals (temperature rise), which were determined by a thermometer. This point-of-care bioassay detected <i>E. coli</i> O157:H7 in the linear range of 10<sup>1</sup>–10<sup>7</sup> CFU mL<sup>−1</sup> and with a detection limit of 14 CFU mL<sup>−1</sup>.
chemistry, analytical
What problem does this paper attempt to address?