A conjugate heat transfer investigation of outer-wall cooling performance in double-wall vane pressure side

Yi WangQingsong HuKefeng YangXing YangXiangyu WangZhenping FengInstitute of Turbomachinery,School of Energy & Power Engineering,Xi'an Jiaotong University,P.R. China
DOI: https://doi.org/10.1080/10407782.2024.2351200
2024-05-16
Numerical Heat Transfer Part A Applications
Abstract:Double wall cooling has significant potential for high-pressure turbine vane cooling technology. Geometric parameters of the double-wall vane play a crucial role in determining the cooling performance. This paper presents a double-wall cooling model with five outer wall thicknesses and three injection angles, using the curvature of the actual pressure side of the engine as a reference.¬†The overall cooling effectiveness is investigated over the range of blowing ratio from 0.5 to 2.5. Results indicate that, at injection angles of 20¬į and 30¬į, an outer-wall thickness of 1.5 D f maximizes the combined benefits of film cooling and thermal conductivity in solid domains. At an injection angle of 40¬į, the blowing ratio becomes a determining factor in selecting the optimal outer wall thickness. Additionally, a reasonable arrangement of pin fins promotes a more uniform outer wall temperature distribution. A thinner outer wall at higher blowing ratios provides optimum overall cooling effectiveness.
thermodynamics,mechanics
What problem does this paper attempt to address?