A meta‐analysis of perfusion parameters affecting weight gain in ex vivo perfusion

Riley Marlar,Fuad Abbas,Rommy Obeid,Sean Frisbie,Adam Ghazoul,Ava Rezaee,Jack Sims,Antonio Rampazzo,Bahar Bassiri Gharb
DOI: https://doi.org/10.1111/aor.14841
2024-08-21
Artificial Organs
Abstract:Oxygen carriers, lower flow rates, and normothermic perfusate temperature appear to improve outcomes in ex vivo machine perfusion. Background Ex vivo machine perfusion (EVMP) has been established to extend viability of donor organs. However, EVMP protocols are inconsistent. We hypothesize that there is a significant relationship between specific parameters during EVMP and perfusion outcomes. Methods A meta‐analysis of literature was conducted in accordance with the Preferred Reporting Items for Systematic Review and Meta‐Analysis (PRISMA) Statement. The search encompassed articles published before July 25, 2023. PubMed, Embase, and CENTRAL databases were screened using search terms "ex‐vivo," "ex‐situ," "machine," and "perfusion." Weight gain, an indicator of organ viability, was chosen to compare outcomes. Extracted variables included perfused organ, warm and cold ischemia time before perfusion, perfusion duration, perfusate flow, pressure, temperature, perfusate composition (presence of cellular or acellular oxygen carrier, colloids, and other supplements) and percent weight change. Data were analyzed using SPSS statistical software. Results Overall, 44 articles were included. Red blood cell‐based perfusates resulted in significantly lower weight gain compared to acellular perfusates without oxygen carriers (11.3% vs. 27.0%, p