Automated contour propagation of the prostate from pCT to CBCT images via deep unsupervised learning

Xiaokun Liang,Jean‐Emmanuel Bibault,Thomas Leroy,Alexandre Escande,Wei Zhao,Yizheng Chen,Mark K. Buyyounouski,Steven L. Hancock,Hilary Bagshaw,Lei Xing
DOI: https://doi.org/10.1002/mp.14755
IF: 4.506
2021-03-01
Medical Physics
Abstract:<section class="article-section__content"><h3 class="article-section__sub-title section1"> Purpose</h3><p>To develop and evaluate a deep unsupervised learning (DUL) framework based on a regional deformable model for automated prostate contour propagation from planning computed tomography (pCT) to cone‐beam CT (CBCT).</p></section><section class="article-section__content"><h3 class="article-section__sub-title section1"> Methods</h3><p>We introduce a DUL model to map the prostate contour from pCT to on‐treatment CBCT. The DUL framework used a regional deformable model via narrow band mapping to augment the conventional strategy. 251 anonymized CBCT images from prostate cancer patients were retrospectively selected and divided into three sets: 180 were used for training, 12 for validation, and 59 for testing. The testing dataset was divided into two Groups. Group one contained 50 CBCT volumes, with one physician‐generated prostate contour on CBCT image. Group two contained 9 CBCT images, each including prostate contours delineated by four independent physicians and a consensus contour generated using the STAPLE method. Results were compared between the proposed DUL and physician‐generated contours through the Dice similarity coefficients (DSC), the Hausdorff distances, and the distances of the center‐of‐mass.</p></section><section class="article-section__content"><h3 class="article-section__sub-title section1"> Results</h3><p>The average DSCs between DUL‐based prostate contours and reference contours for test data in Group one and Group two‐consensus were 0.83 ± 0.04, and 0.85 ± 0.04, respectively. Correspondingly, the mean center‐of‐mass distances were 3.52 mm ± 1.15 mm, and 2.98 mm ± 1.42 mm, respectively.</p></section><section class="article-section__content"><h3 class="article-section__sub-title section1"> Conclusions</h3><p>This novel DUL technique can automatically propagate the contour of the prostate from pCT to CBCT. The proposed method shows that highly accurate contour propagation for CBCT‐guided adaptive radiotherapy is achievable via the deep learning technique.</p></section>
radiology, nuclear medicine & medical imaging
What problem does this paper attempt to address?