An optimised and novel capacitance-based sensor design for measuring void fraction in gas–oil two-phase flow systems

Abdullah M. Iliyasu,Mohammad Hossein Shahsavari,Abdullah S. Benselama,Ehsan Nazemi,Ahmed S. Salama
DOI: https://doi.org/10.1080/10589759.2023.2301492
2024-01-11
Nondestructive Testing And Evaluation
Abstract:This study explores a new electrode configuration for measuring the void fraction of two-phase flows using capacitance-based sensors. The proposed method is considered 'skewed' because of its unique geometric shape, and the performance of the proposed sensor was evaluated and improved via multiple simulations using the COMSOL Multiphysics software. The simulations encompass three different flow patterns, stratified, annular and homogeneous, whose performance themselves were verified in a previous study. The influences of geometric properties and parameters on the sensitivity of the proposed sensor were evaluated to determine an optimal configuration. Furthermore, the sensitivity distribution on different void fractions of the sensor was analysed for various void fractions in different flow patterns. Additionally, the proposed configuration was also compared alongside double-ring and concave sensors to determine the overall sensitivity. At 2.11 pF, the overall sensitivity of the proposed sensor was significantly higher than that of the other sensors. It is worth mentioning that the measurement precision of multiphase flow meters is of high importance, particularly in petroleum industry because of the oil price and also the high amount of transported products.
materials science, characterization & testing
What problem does this paper attempt to address?
The problem that this paper attempts to solve is to measure the void fraction (i.e., the proportion of gas volume to the total volume of the pipeline) in the oil - gas two - phase flow system. Traditional methods usually require separating the two fluids first and then measuring them separately, which are both complicated and time - consuming. However, this paper proposes a new capacitance - based sensor design. By optimizing the electrode configuration, the measurement accuracy and sensitivity are improved, thus providing a non - destructive and more efficient method to measure the void fraction in two - phase flow. This new method is particularly important for the petroleum industry because the oil price fluctuates greatly and the transportation volume is huge, and accurate measurement of two - phase flow parameters is crucial for system design and operation. The paper mentions that the research team used COMSOL Multiphysics software for multiple simulations to evaluate and improve the performance of the proposed sensor. The simulations covered three different flow patterns: stratified flow, annular flow and homogeneous flow. Through these simulations, the research team analyzed the influence of geometric properties and parameters on the sensitivity of the proposed sensor, determined the optimal configuration, and analyzed the sensitivity distribution under different void fractions. In addition, a comparison was made with double - ring and concave sensors. The results show that, with an overall sensitivity of 2.11 pF, the proposed sensor is significantly superior to other types of sensors.