Abstract 13133: Heterogeneous Uptake of [99mTc]microspheres and 201Tl in Skeletal Muscles in Porcine Model of Hindlimb Ischemia
Supum Lee,Pedro Gil de Rubio Cruz,Stephanie Thorn,Zhao Liu,christi hawley,Marina Mamarian,Tymoteusz Turlejski,Ling Jian Meng,Chi Liu,Albert Sinusas,Supum LeePedro Gil de Rubio CruzStephanie ThornZhao Liuchristi hawleyMarina MamarianTymoteusz TurlejskiLing Jian MengChi LiuAlbert SinusasYale Translational Rsch Imaging Cntr,Yale Sch of Medicine,New Haven,CTUniv of Puerto Rico,San Juan,PRYALE UNIVERSITY,New Haven,CTYale PET Cntr,Yale Sch of Medicine,New Haven,CTYale university,New Haven,CTYale Univ,Sch of Medicine,New Haven,CTUniv of Illinois at Urbana-Champaign,Champaign,ILYALE UNIVERSITY SCHOOL MEDICINE,New Haven,CT
DOI: https://doi.org/10.1161/circ.144.suppl_1.13133
IF: 37.8
2021-11-10
Circulation
Abstract:Circulation, Volume 144, Issue Suppl_1, Page A13133-A13133, November 16, 2021. Introduction:There is a need for quantitative methods to evaluate skeletal muscle blood flow in PAD patients. We assessed skeletal muscle blood flow heterogeneity at rest or vasodilator stress using99mTc-microspheres (HSA), that do not cross the capillaries, and201Tl, a freely diffusible radiotracer, in a pig hindlimb ischemia model.Methods:Following acute right femoral artery ligation, pigs (n=8) were injected with either201Tl or HSA at rest (n=2 per tracer) or under adenosine-stress (n=2 per tracer). Ex vivo SPECT/CT imaging was performed on excised ischemic (I) and non-ischemic (NI) gastrocnemius (GM) and soleus (SM) muscles. SPECT images were analyzed for the ischemic/nonischemic (I/NI) activity ratio, tracer heterogeneity as indicated by the coefficient of variance (CV) of signal intensity and image intensity histograms.Results:The rest201Tl I/N ratio for SM was higher (0.86±0.08) compared to stress (0.64±0.16), with no difference in GM. In contrast, the I/N ratio for HSA was near normal in both muscle groups at rest (GM: 0.80±0.21, SM: 1.06±0.45) although decreased during stress (GM: 0.70±0.04, SM: 0.71±0.12). Rest201Tl displayed uniformly low CV in both I (GM: 0.43, SM: 0.43) and NI muscles (GM: 0.37, SM: 0.43). Corresponding CV for stress201Tl were similar (I - GM: 0.41, SM: 0.42; NI - GM: 0.41, SM: 0.46). Rest HSA CV were higher in I (GM: 0.92, SM: 1.03) and NI (GM: 0.67, SM: 0.69) muscle, although there was greater heterogeneity in the I muscles assessed with HSA. Stress HSA CV decreased in both I (GM: 0.60, SM: 0.73) and NI (GM: 0.52, SM: 0.51). Figure displays representative count histograms.Conclusions:201Tl displayed less heterogeneity than HSA.201Tl appears to be more sensitive at detecting reduced blood flow at rest, due to changes in microcirculation. There was no change in the I/NI ratio during201Tl stress due to capillary recruitment, although HSA did demonstrate a decrease in the I/NI ratio with vasodilation, reflecting proximal vascular occlusion.
cardiac & cardiovascular systems,peripheral vascular disease