Effect of passive auxiliary feedwater system on mitigation of DEC accidents: Part I. MSGTR, SBLOCA-LOSI, and SBO

Youngjae Park,Seong-Su Jeon,Dong-Young Lee,Young Wook Chung,Sang Gyun Nam,Do Hyun Hwang
DOI: https://doi.org/10.1016/j.anucene.2024.110643
IF: 1.9
2024-05-26
Annals of Nuclear Energy
Abstract:Multiple Steam Generator Tube Ruptures (MSGTR), Small Break Loss of Coolant Accident with Loss of Safety Injection (SBLOCA-LOSI), and Station Blackout (SBO) are Design Extension Condition (DEC) accidents where the SG secondary-side cooling with operator actions are essential for the mitigation of the accidents. In the Republic of Korea, the Passive Auxiliary Feedwater System (PAFS) was developed to replace the active Auxiliary Feedwater System (AFWS). It is important to examine the existing accident mitigation strategies and evaluate whether they can be effectively applied to DECs using PAFS as well. To investigate the changes in accident mitigation characteristics and operator actions when PAFS is implemented instead of AFWS, the DEC accidents such as MSGTR, SBLOCA-LOSI, and SBO are analyzed with RELAP5/MOD3.3. Research results presented in this paper have significant implications and can be utilized to improve the accident mitigation strategies and the operator training for DEC accidents where PAFS is implemented.
nuclear science & technology
What problem does this paper attempt to address?