Evaluation of agricultural non-point source pollution using an in-situ and automated photochemical flow analysis system

Yongqi Chen,Muhammad Awais,Junfeng Wu,Zhenfeng Li,Syed Muhammad Zaigham Abbas Naqvi,Mukhtar Iderawumi Abdulraheem,Hao Zhang,Ling Wang,Wei Zhang,Vijaya Raghavan,Jiandong Hu
DOI: https://doi.org/10.1038/s41598-024-65251-6
IF: 4.6
2024-06-24
Scientific Reports
Abstract:Off-line leachate collection from agricultural landscapes cannot guarantee precise evaluation of agricultural non-point source (ANPS) due to geospatial variations, time, and transportation from the field to the laboratory. Implementing an in-situ nitrogen and phosphorous monitoring system with a robust photochemical flow analysis is imperative for precision agriculture, enabling real-time intervention to minimize non-point source pollution and overcome the limitations posed by conventional analysis in laboratory. A reliable, robust and in-situ approach was proposed to monitor nitrogen and phosphorous for determining ANPS pollution. In this study, a home-made porous ceramic probe and the frequency domain reflectometer (FDR) based water content sensors were strategically placed at different soil depths to facilitate the collection of leachates. These solutions were subsequently analyzed by in-situ photochemical flow analysis monitoring system built across the field to estimate the concentrations of phosphorus and nitrogen. After applying both natural and artificial irrigation to the agricultural landscape, at least 10 mL of soil leachates was consistently collected using the porous ceramic probe within 20 min, regardless of the depth of the soil layers when the volumetric soil water contents are greater than 19%. The experimental results showed that under different weather conditions and irrigation conditions, the soil water content of 50 cm and 90 cm below the soil surface was 19.58% and 26.08%, respectively. The average concentrations of NH 4 + -N, NO 3 − -N, PO 4 3− are 0.584 mg/L, 15.7 mg/L, 0.844 mg/L, and 0.562 mg/L, 16.828 mg/L and 0.878 mg/L at depths of 50 cm and 90 cm below the soil surface, respectively. Moreover, the comparison with conventional laboratory spectroscopic analysis confirmed R 2 values of 0.9951, 0.9943, 0.9947 average concentration ranges of NH 4 + -N, NO 3 − -N, and PO 4 3− , showcasing the accuracy and reliability of robust photochemical flow analysis in-situ monitoring system. The suggested monitoring system can be helpful in the assessment of soil nutrition for precision agriculture.
multidisciplinary sciences
What problem does this paper attempt to address?
This paper attempts to solve several key problems in agricultural non - point source pollution (ANPS) assessment: 1. **Limitations of data collection and analysis**: Traditional methods for assessing agricultural non - point source pollution usually require offline collection of soil leachate and transporting it to the laboratory for analysis. This method is not only time - consuming, but also may cause sample deterioration during transportation, affecting the accuracy of the results. 2. **Requirement for real - time monitoring**: In order to achieve precision agriculture, a method that can monitor the concentrations of nitrogen and phosphorus in the soil in real - time is needed, so as to take timely measures to reduce non - point source pollution. 3. **Deficiencies of existing technologies**: Existing nitrogen and phosphorus measurement technologies mostly rely on laboratory - based spectral analysis methods, such as Fourier transform infrared spectroscopy (FTIR), Raman spectroscopy and near - infrared spectroscopy (NIR). Although these methods have high detection accuracy and a wide detection range, the stability and reliability of the equipment in complex farmland environments are poor and cannot meet the needs of on - site detection. For this reason, this paper proposes a reliable and automated photochemical flow analysis system for on - site monitoring of nitrogen and phosphorus concentrations in agricultural non - point source pollution. Specifically, the system includes the following key parts: - **Self - made porous ceramic probe**: Used to collect leachate from different soil depths. - **Frequency domain reflectometer (FDR) soil moisture sensor**: Used to monitor soil moisture content to trigger the collection of leachate. - **Automated photochemical flow analysis monitoring system**: Used to analyze the nitrogen and phosphorus concentrations in the leachate on - site. Through this system, researchers can quickly and accurately collect and analyze soil leachate under different weather and irrigation conditions, thus providing a more efficient and accurate method for assessing agricultural non - point source pollution.