Particle-size Measurements in a Micro-channel with Image Dynamic Light Scattering Method

Lili Liu,Xiaoshu Cai,Jie Zhang,Chengze Xu
DOI: https://doi.org/10.1016/j.proeng.2015.01.211
2015-01-01
Procedia Engineering
Abstract:Conventional dynamic light scattering (DLS) using a CCD camera as optical area detector (here we called Image Dynamic Light Scattering method, for the data acquired by images) has been developed successfully. We present a model experiment in a micro-channel to study flowing Brownian motion systems of polystyrene latex particles by using Image Dynamic Light Scattering method (IDLS). The modified correlation function proposed by Chowdhury et al, which is applied to the analysis of extracting the size and velocity of laminar flowing particulate dispersions, is used in the paper to obtain the particle size from the scattered light signals. The new method allows for much shorter measurement time compared to conventional DLS. As the inversion algorithm of polydisperse system is yet very complex, the measurement of the paper is for monodisperse polystyrene latex particles.
What problem does this paper attempt to address?