Cooling operation strategies in a typical neighborhood mosque: A Case study on electricity consumption, CO 2 emissions, and thermal comfort

Ahmet Yüksel,Müslüm Arıcı,Michal Krajčík,Mihriban Civan,Hasan Karabay
DOI: https://doi.org/10.1016/j.enbuild.2024.114073
IF: 7.201
2024-03-15
Energy and Buildings
Abstract:Mosques are used five times daily by Muslims. Therefore, it is crucial to maintain adequate thermal conditions in mosques in the hot summer months. In this study, a simulation model was developed in the DesignBuilder program to investigate various operation strategies of two air conditioners (A/Cs) used for cooling of a typical medium-sized uninsulated neighborhood mosque. The A/Cs operation strategies were as follows: Case-I: continuous A/Cs operation, Case-II: intermittent A/Cs operation during prayer times (starting 10, 20, 30 or 60 min before daily prayers except Fajr prayers), Case-III: A/Cs operating at night (from the Isha prayer until the end of the Fajr prayer), Case-IV: A/Cs operated during the day (from the Fajr prayer to the end of the Isha prayer), and Case-V: A/Cs operated during the afternoon (from the Zuhr prayer until the end of the Isha prayer). The predicted percentage of dissatisfied reached up to 30 % during the Asr prayer despite continuous operation in Case-I. Adequate thermal conditions could not be achieved in the other cases either. All cases, except Case-II (operation before and during prayer times), required higher electricity consumption than that of the invoice data. Therefore, it is recommended to adapt the A/Cs capacity based on changes in outdoor and indoor thermal conditions and focus on zonal cooling in the mosque.
energy & fuels,construction & building technology,engineering, civil
What problem does this paper attempt to address?