Deep Convolutional Neural Networks Provide Motion Grading for High-Resolution Peripheral Quantitative Computed Tomography of the Scaphoid

Stefan Benedikt,Philipp Zelger,Lukas Horling,Kerstin Stock,Johannes Pallua,Michael Schirmer,Gerald Degenhart,Alexander Ruzicka,Rohit Arora
DOI: https://doi.org/10.3390/diagnostics14050568
IF: 3.6
2024-03-07
Diagnostics
Abstract:In vivo high-resolution peripheral quantitative computed tomography (HR-pQCT) studies on bone characteristics are limited, partly due to the lack of standardized and objective techniques to describe motion artifacts responsible for lower-quality images. This study investigates the ability of such deep-learning techniques to assess image quality in HR-pQCT datasets of human scaphoids. In total, 1451 stacks of 482 scaphoid images from 53 patients, each with up to six follow-ups within one year, and each with one non-displaced fractured and one contralateral intact scaphoid, were independently graded by three observers using a visual grading scale for motion artifacts. A 3D-CNN was used to assess image quality. The accuracy of the 3D-CNN to assess the image quality compared to the mean results of three skilled operators was between 92% and 96%. The 3D-CNN classifier reached an ROC-AUC score of 0.94. The average assessment time for one scaphoid was 2.5 s. This study demonstrates that a deep-learning approach for rating radiological image quality provides objective assessments of motion grading for the scaphoid with a high accuracy and a short assessment time. In the future, such a 3D-CNN approach can be used as a resource-saving and cost-effective tool to classify the image quality of HR-pQCT datasets in a reliable, reproducible and objective way.
medicine, general & internal
What problem does this paper attempt to address?
The problem that this paper attempts to solve is the impact of image artifacts caused by patient movement on image quality in high - resolution peripheral quantitative computed tomography (HR - pQCT) images, and how to evaluate the quality of these images through deep - learning techniques, especially three - dimensional convolutional neural networks (3D - CNN). Specifically, the main problems faced by the researchers are: 1. **Standardized evaluation of image artifacts**: Currently, the evaluation of motion artifacts in HR - pQCT images mainly depends on manual visual grading. This method is highly subjective and has poor consistency among different observers. 2. **Improving evaluation efficiency and accuracy**: Manual evaluation is not only time - consuming but also easily affected by the operator's experience and technical conditions, resulting in inconsistent evaluation results. 3. **Developing automated tools**: The researchers hope to develop an automated tool based on 3D - CNN that can quickly and accurately evaluate the quality of HR - pQCT images, reduce human errors, and improve evaluation efficiency. To this end, the researchers designed a 3D - CNN model for automatically evaluating motion artifacts in HR - pQCT images and compared it with the manual evaluation results of three experts to verify the accuracy and reliability of the model. The goal of the study is to develop a system that can efficiently and objectively evaluate the quality of HR - pQCT images in clinical practice.