Numerical Analysis of the Effect of Jet-Fan Operation Condition on Smoke Movement and Visibility in Tunnel Fire
Ha Thien Khieu,Ji Tea Kim,K. Hong,H. Ryou
DOI: https://doi.org/10.11159/ENFHT19.153
2019-04-01
Abstract:Every year, many fires occur in the tunnels, with many causalities because of smoke. For this reason, the ventilation system in the tunnel is one of the most critical issues for reducing human causalities. Generally, the jet fan is used for a ventilation system for reducing air pollution in many tunnels. However, when the fire occurs, and jet fan operates, the smoke stratification also happens, it causes a difficulty for people to evacuate. Accordingly, jet fan operating condition is essential to avoid smoke stratification. Besides, the effect of jet-fan on the smoke movement and visibility in the tunnel is also necessarily studied. In this paper, we performed a numerical simulation about the effect of a jet fan on the smoke movement and visibility with variable jet fans speed and different operating condition. The tunnel length is 400 m, there are four jet fans inside, two jet fans are located near the exit position of the tunnel with a diameter of 1.03 m, the distance from it to the exit position and the ceilings are 10 m and 1.6 m, respectively. Two other jet fans are located at the opposite side, and it is nearby the entrance position with same diameter and distance. The jet fans speeds are from 12.5 m/s, 20 m/s, and 25 m/s, respectively. Besides, a different number of jet fans also have been carried out with two jet fans at the exit operate, two jet fans at the entrance operate, and all jet fans operate, respectively. The fire source data was 3.7MW which obtained by our one vehicle sedan fire experiment. Results show that when only two jet fans at the exit are operated, the smoke spreads to both sides, but with other cases, the smoke tends to go to exit direction. Besides, when two jet fans at the entrance are operated, and all jet fans are operated, there is smoke stratification in the tunnel, because in these cases, a large amount of air has been transported into the tunnel by the jet fan operating at the entrance, so the smoke and air are mixed, consequently, the smoke stratification occurs. Furthermore, when jet fan operated at a lower speed, the smoke back-layering length is longer than when operated at higher speed, it also depends on a large amount of air has been transported with high speed. Therefore, it is difficult for evacuation. From the above reasons, jet fans operating condition should be considered for designing a mechanical ventilation system.
Environmental Science,Engineering