A mouse model for calculating cross‐organ beta doses from yttrium‐90‐labeled immunoconjugates

J. Kuhn,C. Badger,J. David Beatty,D. Fisher,B. Beatty,T. Edmond Hui,L. Williams,C. Nourigat
DOI: https://doi.org/10.1002/1097-0142(19940201)73:3+<951::AID-CNCR2820731330>3.0.CO;2-1
IF: 6.9209
1994-02-01
Cancer
Abstract:Background. The organs of laboratory mice used in radioimmunotherapy experiments are relatively small compared to the ranges of high‐energy yttrium‐90 (Y‐90) beta particles. Current Medical Internal Radiation Dose (MIRD) dosimetry methods do not account for beta energy that escapes an organ. A dosimetry model was developed to provide more realistic dose estimates for organs in mice who received Y‐90‐labeled antibodies by accounting for physical and geometric factors, loss of beta dose due to small organ sizes, and cross‐organ doses.
Medicine,Physics