The Role of Dendritic Mesoporous Silica Nanoparticles’ Size for Quantum Dots Enrichment and Lateral Flow Immunoassay Performance

Fang Gao,Yang Liu,Chang Lei,Chao Liu,Hao Song,Zhengying Gu,Pei Jiang,Sheng Jing,Jingjing Wan,Chengzhong Yu
DOI: https://doi.org/10.1002/smtd.202000924
IF: 12.4
2021-02-02
Small Methods
Abstract:<p>Using dendritic mesoporous silica nanoparticles (DMSNs) for quantum dots (QDs) enrichment and signal amplification is an emerging strategy for improving the detection sensitivity of lateral flow immunoassay (LFIA). In this study, a new and convenient approach is developed to prepare water‐dispersible DMSNs‐QDs. A series of DMSNs with various diameters (138, 251, 368, and 471 nm) are studied for loading QDs and LFIA applications. The resultant water‐dispersible DMSNs‐QDs exhibit a high fluorescence retention of 81.8%. The increase in particle size from 138 to 471 nm results in an increase in loading capacity of QDs and a decrease in binding quantity of the DMSNs‐QDs in the test line of LFIA. This trade‐off leads to an optimal DMSNs‐QDs size of 368 nm with a limit of detection reaching 10 pg mL<sup>−1</sup> (equivalent to 9.0 × 10<sup>−14</sup> <span class="smallCaps">m</span>) for the detection of C‐reactive protein, which is nearly an order of magnitude more sensitive than the literature. To the best of the authors' knowledge, this study is the first to demonstrate the distinctive role of DMSN's size for QDs enrichment and LFIA. The strategy developed from this work is useful for the rational design of high‐quality QDs‐based nanoparticles for ultrasensitive detection.</p>
materials science, multidisciplinary,chemistry, physical,nanoscience & nanotechnology
What problem does this paper attempt to address?
This paper aims to solve the problem of insufficient detection sensitivity in lateral - flow immunoassay (LFIA). Specifically, the paper improves the detection sensitivity of LFIA by studying the influence of the size of dendritic mesoporous silica nanoparticles (DMSNs) on the enrichment of quantum dots (QDs) and the performance of LFIA. It is found that by optimizing the size of DMSNs, the balance between the optimal loading amount and the binding amount of QDs can be achieved, thereby significantly improving the detection sensitivity of LFIA. For example, DMSNs with different diameters (138, 251, 368, and 471 nm) were prepared in the study, and it was found that the DMSNs with a diameter of 368 nm showed the best sensitivity when detecting C - reactive protein (CRP), and its limit of detection (LOD) reached 10 pg/mL (equivalent to 9.0 × 10\(^{-14}\) M), which is nearly an order of magnitude higher than the results reported in the existing literature. This research provides new strategies and methods for high - sensitivity bio - detection.