Compact Magneto‐Fluorescent Colloids by Hierarchical Assembly of Dual‐Components in Radial Channels for Sensitive Point‐of‐Care Immunoassay

Liang Huang,Yuxing Zhang,Tao Liao,Kui Xu,Chenxing Jiang,Dinglv Zhuo,Yang Wang,Hui‐Min Wen,Jing Wang,Lijiao Ao,Jun Hu
DOI: https://doi.org/10.1002/smll.202100862
IF: 13.3
2021-05-25
Small
Abstract:<p>Exploring signal amplification strategies to enhance the sensitivity of lateral flow immunoassay (LFIA) is of great significance for point-of-care (POC) testing of low-concentrated targets in the field of in vitro diagnostics. Here, a highly-sensitive LFIA platform using compact and hierarchical magneto–fluorescent assemblies as both target-enrichment substrates and optical sensing labels is demonstrated. The large-pored dendritic templates are utilized for high-density incorporation of both superparamagnetic iron oxide nanoparticles (IOs) and quantum dots (QDs) within the vertical channels. The hierarchical structure is built via affinity-driven assembly of IOs and QDs from organic phase with silica surface and mercapto-organosilica intermediate layer, respectively. The sequential assembly with central–radial channels enables 3D loading of dual components and separately controlling of discrete functionalities. After the alkyl-organosilica encapsulation and silica sealing, the composite spheres exhibit high stabilities and compatibility with LFIA for procalcitonin (PCT) detection. With the assistance of liquid-phase antigen-capturing, magnetic enrichment, and fluorescence-signal amplification, a limit of detection of 0.031 ng mL<sup>−1</sup> for PCT is achieved with a linear range from 0.012 to 10 ng mL<sup>−1</sup>. The current LFIA is robust and validated for PCT detection in real serum, which holds great diagnostic significance for precise guidance of antibiotic therapy with POC manner.</p>
materials science, multidisciplinary,chemistry, physical,physics, applied, condensed matter,nanoscience & nanotechnology
What problem does this paper attempt to address?
This paper aims to address the issue of insufficient sensitivity in lateral flow immunoassay (LFIA) for detecting low concentrations of target substances in point-of-care (POC) diagnostics. Specifically, the paper proposes a novel magnetic-fluorescent composite material that can significantly enhance the detection sensitivity of the LFIA platform through magnetic enrichment and fluorescence signal amplification. This method utilizes the orderly assembly of iron oxide nanoparticles (IOs) and quantum dots (QDs) in a dendritic silica template to form composite microspheres with high-density magnetic and fluorescent components. These composite microspheres not only maintain good dispersibility and stability but also enable effective detection of procalcitonin (PCT) in actual serum samples, with a detection limit of 0.031 ng/mL and a linear range of 0.012 to 10 ng/mL. This study provides a new solution for the application of LFIA technology in clinical diagnostics, particularly in improving the accuracy of antibiotic treatment guidance.