Abbreviated breast MRI or digital breast tomosynthesis for breast cancer detection in dense breasts? A retrospective preliminary study with comparable results
M.T. Ramli Hamid,N. Ab Mumin,S. Abdul Hamid,M.S. Ahmad Saman,K. Rahmat
DOI: https://doi.org/10.1016/j.crad.2023.12.016
IF: 3.389
2024-01-12
Clinical Radiology
Abstract:AIM To compare the diagnostic performance of abbreviated breast magnetic resonance (AB-MR) imaging (MRI) and digital breast tomosynthesis (DBT) for breast cancer detection in Malaysian women with dense breasts, using histopathology as the reference standard. MATERIALS AND METHODS This was a single-centre cross-sectional study of 115 women with American College of Radiology (ACR) Breast Imaging-Reporting and Data System (BIRADS) breast density C and D on DBT with breast lesions who underwent AB-MR from June 2018 to December 2021. AB-MR was performed on a 3 T MRI system with an imaging protocol consisting of three sequences: axial T1 fat-saturated unenhanced; axial first contrast-enhanced; and subtracted first contrast-enhanced with maximum intensity projection (MIP). DBT and AB-MR images were evaluated by two radiologists blinded to the histopathology and patient outcomes. Diagnostic accuracy (sensitivity, specificity, positive predictive value [PPV] and negative predictive value [NPV]) was assessed. RESULT Of the 115 women, the mean age was 50.6 years. There were 48 (41.7%) Malay, 54 (47%) Chinese, and 12 (10.4%) Indian women. The majority ( n= 87, 75.7%) were from the diagnostic population. Sixty-one (53.1%) were premenopausal and 54 (46.9%) postmenopausal. Seventy-eight (72.4%) had an increased risk of developing breast cancer. Ninety-one (79.1%) women had density C and 24 (20.9%) had density D. There were 164 histopathology-proven lesions; 69 (42.1%) were malignant and 95 (57.9%) were benign. There were 62.8% ( n= 103/164) lesions detected at DBT. All the malignant lesions 100% ( n= 69) and 35.7% ( n= 34) of benign lesions were detected. Of the 61 lesions that were not detected, 46 (75.4%) were in density C, and 15 (24.6%) were in density D. The sensitivity, specificity, PPV, and NPV for DBT were 98.5%, 34.6%, 66.3%, and 94.7%, respectively. There were 65.2% ( n= 107/164) lesions detected on AB-MR, with 98.6% ( n= 68) malignant and 41.1% (39) benign lesions detected. The sensitivity, specificity, PPV, and NPV for AB-MR were 98.5%, 43.9%, 67.2%, and 96.2%, respectively. One malignant lesion (0.6%), which was a low-grade ductal carcinoma in-situ (DCIS), was missed on AB-MR. CONCLUSION The present findings suggest that both DBT and AB-MR have comparable effectiveness as an imaging method for detecting breast cancer and have high NPV for low-risk lesions in women with dense breasts.
radiology, nuclear medicine & medical imaging