Ultrasensitive Detection of RNA with Single-Base Resolution by Coupling Electrochemical Sensing Strategy with Chimeric DNA Probe-Aided Ligase Chain Reaction

Guang-Xian Zhong,Chen-Liu Ye,Hong-Xiang Wei,Liang-Yong Yang,Qing-Xia Wei,Zhou-Jie Liu,Leng-Xi Fu,Xin-Hua Lin,Jin-Yuan Chen
DOI: https://doi.org/10.1021/acs.analchem.0c03563
IF: 7.4
2020-12-07
Analytical Chemistry
Abstract:Accurate and sensitive detection of single-base mutations in RNAs is of great value in basic studies of life science and medical diagnostics. However, the current available RNA detection methods are challenged by heterogeneous clinical samples in which trace RNA mutants usually existed in a large pool of normal wild sequences. Thus, there is still great need for developing the highly sensitive and highly specific methods in detecting single-base mutations of RNAs in heterogeneous clinical samples. In the present study, a new chimeric DNA probe-aided ligase chain reaction-based electrochemical method (cmDNA-eLCR) was developed for RNA mutation detection through the BSA-based carrier platform and the horseradish peroxidase-hydrogen peroxide-tetramethylbenzidine (HRP-H<sub>2</sub>O<sub>2</sub>-TMB) system. The denaturing polyacrylamide gel electrophoresis and a fluorophore-labeled probe was ingeniously designed to demonstrate the advantage of cmDNA in ligation to normal DNA templated by RNA with the catalysis of T4 RNA ligase 2 as well as its higher selectivity than DNA ligase system. Finally, the proposed cmDNA-eLCR, compared with the traditional eLCR, showed excellent performance in discriminating single base-mismatched sequences, where the signal response for mismatched targets at a high concentration could overlap completely with that for the blank control. Besides, this cmDNA-eLCR assay had a wide linear range crossing six orders of magnitude from 1.0 × 10<sup>-15</sup> to1.0 × 10<sup>-10</sup> M with a limit of detection as low as 0.6 fM. Furthermore, this assay was applied to detect RNA in real sample with a satisfactory result, thereby demonstrating its great potential in diagnosis of RNA-related diseases.
chemistry, analytical
What problem does this paper attempt to address?
The paper aims to address the issue of detecting single-base mutation RNA with high sensitivity and specificity in complex clinical samples. Specifically, current RNA detection methods face challenges when dealing with heterogeneous clinical samples because trace amounts of RNA mutants are often present within a large number of normal wild-type sequences. Therefore, there is an urgent need to develop a method that can efficiently detect single-base mutation RNA in these complex samples. The paper proposes a new electrochemical method based on chimeric DNA probe-assisted ligase chain reaction (cmDNA-eLCR) to achieve this goal through a BSA carrier platform and a horseradish peroxidase-hydrogen peroxide-tetramethylbenzidine (HRP-H₂O₂-TMB) system. This method not only has high sensitivity and a wide linear range but also can effectively distinguish high concentrations of single-base mismatch sequences, thereby detecting trace amounts of mutant RNA in clinical samples.