Analysis of a Cyclotron Based 400 MeV/u Driver System for a Radioactive Beam Facility

F. Marti,R.C. York,H. Blosser,M.M. Gordon,D. Gorelov,T. Grimm,D. Johnson,P. Miller,E. Pozdeyev,J. Vincent,X. Wu,A. Zeller
DOI: https://doi.org/10.48550/arXiv.nucl-ex/9908013
1999-08-21
Abstract:The creation of intense radioactive beams requires intense and energetic primary beams. A task force analysis of this subject recommended an acceleration system capable of 400 MeV/u uranium at 1 particle uA as an appropriate driver for such a facility. The driver system should be capable of accelerating lighter ions at higher intensity such that a constant final beam power (~100kW) is maintained. This document is a more detailed follow on to the previous analysis of such a system incorporating a cyclotron. The proposed driver pre-acceleration system consists of an ion source, radio frequency quadrupole, and linac chain capable of producing a final energy of 30 MeV/u and a charge (Q) to mass (A) of Q/A ~1/3. This acceleration system would be followed by a Separated Sector Cyclotron with a final output energy of 400 MeV/u. This system provides a more cost-effective solution in terms of initial capital investment as well as of operation compared to a fully linac system with the same primary beam output parameters.
Nuclear Experiment,Accelerator Physics
What problem does this paper attempt to address?
The main problem that this paper attempts to solve is to design and analyze a 400 MeV/u cyclotron - based drive system for generating a high - intensity radioactive beam facility. Specifically, this system is designed to meet the following requirements: 1. **Provide high - intensity and high - energy primary beams**: In order to create intense radioactive beams, a drive system that can provide high - intensity (for example, 1 particle µA) and high - energy (for example, 400 MeV/u uranium) primary beams is required. 2. **Adapt to the acceleration requirements of multiple ions**: This drive system not only needs to accelerate uranium ions but also needs to be able to accelerate lighter ions and maintain a constant final beam power (about 100 kW). This means that the system must be able to switch flexibly between different ion species and work efficiently under different Q/A (charge - to - mass ratio) conditions. 3. **Cost - effectiveness**: Compared with the scheme using only linear accelerators, this cyclotron system should provide a more cost - effective solution, including initial capital investment and operating costs. ### System Overview This system consists of two main parts: - **Pre - accelerator system**: It includes an ion source, a radio - frequency quadrupole (RFQ), and a series of linear accelerators (linac), which accelerate ions to 30 MeV/u with Q/A ≈ 1/3. - **Separated - sector cyclotron (SSC)**: It further accelerates ions to 400 MeV/u. ### Key Technical Challenges and Solutions 1. **Stripping system of the pre - accelerator system**: - It is necessary to adjust the Q/A ratios of different elements through different stripping foils to ensure that all ions can reach the required Q/A ≈ 1/3. - Different elements need to be stripped at different positions, so three stripping foils are required, located at 75 MV, 140 MV, and 204 MV respectively. 2. **Longitudinal injection requirements**: - The longitudinal acceptance of the cyclotron is relatively large (≈40 π keV/u ns), while the longitudinal emittance of the linear accelerator is relatively small (≈2 π keV/u ns). Therefore, appropriate adjustment of the longitudinal phase space is required to match the difference between them. - Using longitudinal dynamics adjustment methods, such as changing the synchronous phase or rotating mismatched buckets, can effectively adjust the beam parameters. 3. **Design of the main cyclotron**: - **Q/A range**: Through detailed evaluation, the Q/A range is determined to be 1/3 ± 10.1% to cover almost all stable isotopes. - **Correction coils**: In order to adapt to different Q/A ratios, 14 correction coils are designed to fine - tune the magnetic field distribution and ensure isochronism. - **Vacuum requirements**: In order to minimize beam loss, the design goal is to maintain the vacuum pressure at 1 x 10^-7 torr. ### Summary This paper analyzes in detail how to design an efficient cyclotron - drive system to meet the requirements of radioactive beam facilities. By optimizing the designs of the pre - accelerator and the main cyclotron, this system can reduce construction and operating costs while ensuring performance.