Comparative Study on PM_(10) Microstructure and Heavy Metals Distribution in Emissions of Coal Combustion Sources
YUE Yong,YAO Qiang,SONG Qiang,LI Shui-qing,WANG Hui
DOI: https://doi.org/10.3321/j.issn:0258-8013.2007.35.007
2007-01-01
Abstract:Three different sources of fly-ash particles were directly sampled from a pulverized coal-fired (PC) boiler, a coal-water mixture fired (CWM) boiler and a circulating fluidized bed (CFB) boiler in flue by 8-stage Andersen impactor with aerodynamic diameter separation. Characteristics of samples in different stages were analyzed by means of a scanning electron microscopy (SEM) and an inductively coupled plasma atomic emission spectrometry (ICP-AES). The microstructures of PM10 and enrichment quantities of 8 elements (As, Pb, Cr, Cd, Ni, Co, Cu, Zn) in different size particles were studied. The results show that over 90% of PM10 particulates from PC and CWM boilers are in regular spherical. However, the particulates from CFB boiler are mainly irregular, flake-like and floccus-like in shape. The result of eight elements enrichments in fly-ash particles is AsPbCd, ZnNiCoCu, Cr. Enrichment quantities of elements fold increase with decreasing of particle size in PC and CWM boilers. The relative enrichment factor of As is 30 and 23 in PC and CWM at the last stage, it of Pb is 16 and 13, and Ni, Co, Cu, Cr have enrichment times of 4-8. While in CFB boiler, there is nearly no enrichment of elements due to low operating temperature.