Full investigation of frequency locking loop model for high-Q Fabry-Pérot cavity acoustic sensor

Chen Chen,Yongqiu Zheng,Jiamin Chen,Liyun Wu,Xinyu Zhao,Chenyang Xue
DOI: https://doi.org/10.1016/j.optlastec.2021.106976
2021-07-01
Abstract:<p>The high-quality-factor (high-Q) Fabry-Pérot (F-P) cavity offers significant advantages for use in high-sensitivity detection. A frequency locking loop model that uses a high-Q F-P cavity as the sensing element for an acoustic sensor is investigated in this work. The frequency locking technology of the high-Q F-P cavity is indispensable for accurate sensing of acoustic signals. The effects of the total loop gain, the integral time, the differential constant and the time constant on the frequency locking and the acoustic performance are studied comprehensively. For an F-P cavity with a quality value of 4.05 × 10<sup>9</sup>, accurate locking of the resonance frequency and detection uncertainty of 7.27 × 10<sup>−5</sup> for acoustic signals are achieved. These results indicate that the improvement in the performance of the acoustic sensor using this high-Q F-P cavity benefits from optimization of the frequency locking loop parameters.</p>
optics,physics, applied
What problem does this paper attempt to address?