Enhanced electrocatalytic activity of hafnium doped tungsten oxide (Hf-WO 3 ) for ultrasensitive detection of nonsteroidal anti-inflammatory drug

Mahesh M. Shanbhag,Davalasab Ilager,Shankara S. Kalanur,Nagaraj P. Shetti,Abdullah N. Alodhayb,Hamad Albrithen,Khalid Alhussaini,Abdulaziz K. Assaifan
DOI: https://doi.org/10.1016/j.matchemphys.2024.129975
IF: 4.778
2024-09-25
Materials Chemistry and Physics
Abstract:Efficient hafnium-doped tungsten oxide nanoparticles (Hf-WO 3 ) were developed by hydrothermal approach and characterization was carried out by X-ray diffraction pattern (XRD), transmission electron microscopy (TEM), high resolution-transmission electron microscopy (HR-TEM), scanning transmission electron microscopy (STEM), X-ray photoelectron spectroscopy (XPS) and electrochemical impedance spectroscopy (EIS) techniques. Cyclic voltammetry (CV) and square wave voltammetry (SWV) techniques were employed to assess the electrochemical response of the fabricated carbon paste electrodes (CPE) for the analysis of mefenamic acid (MA). The objective of this work is to develop and optimize parameters to enhance the selectivity and sensitivity of Hf-WO 3 modified sensor for the trace-level detection of MA, addressing its critical importance in both pharmaceutical and environmental analysis. The Hf-WO 3 predominantly showed a monoclinic phase with some hexagonal peaks, confirming its good crystallinity and 1-D structure, which enhances charge transport and catalytic sites. XPS analysis confirmed the formation of pure Hf-WO 3 by showing distinct W and Hf peaks and verifying their valences: W in the +6 state and Hf in the +4 state. CV showed that the Hf-WO 3 /CPE greatly enhances the electrochemical oxidation of MA compared to unmodified and tungsten oxide-modified electrodes, with a six-fold increase in peak current and notable redox activity attributed to improved surface properties and charge transfer efficiency. Under optimum experimental conditions, the Hf-WO 3 /CPE exhibits a low limit of detection (LOD) of 3.94 nM with dynamic concentration linearity ranging from 0.01 to 100.0 μM with good sensitivity of 1.74 μAμM −1 cm −2 . Furthermore, the Hf-WO 3 /CPE was employed in real-time analysis of MA in spiked urine samples and pharmaceutical tablet samples, which showed satisfactory recovery results ⁓ 98 %. Moreover, the electrode showed good stability over multiple measurements, and these results demonstrate that Hf-WO 3 /CPE is a promising sensor for MA detection.
materials science, multidisciplinary
What problem does this paper attempt to address?