Azo-receptor conjoined mesoporous honeycomb silica framework as solid-state chromogenic sensor for capturing ultra-trace cadmium ions from environmental/industrial samples
Anju P Veedu,Balasurendran Jeyakumar,Akhila Maheswari Mohan,K. Satheesh,K. C. Pitchaiah,Manjula Muthurathinam,C. V. S. Brahmananda Rao,Nagarajan Sivaraman,Prabhakaran Deivasigamani
DOI: https://doi.org/10.1039/d4ta04574b
IF: 11.9
2024-10-11
Journal of Materials Chemistry A
Abstract:The work focuses on a pollution-free ultra-portable solid-state opto-chemosensor for sensing noxious Cd 2+ from environmental, industrial and non-industrial samples. An amphiphilic heterocyclic azo-receptor, (E)-4-((4,5-dimethylthiazol-2-yl)diazenyl)-6-hexylbenzene-1,3-diol (DMTHBD) is meticulously interlaced to the mesopore honeycomb structured silica monolith framework (MHSF). The aqua-compatible optical sensor (DMTHBD@MHSF) proffers remarkable structural integrity, surface morphology and porosity. The MHSF and DMTHBD@MHSF materials are characterized using powder X-ray diffraction, X-ray photoelectron spectroscopy, Fourier Transform infrared spectroscopy, high-resolution transmission electron microscopy, field-emission scanning electron microscopy, energy dispersive X-ray analysis, selected area electron diffraction, elemental mapping analysis, thermogravimetric/differential thermal analysis, Brunauer-Emmett-Teller (surface area) and Barrett-Joyner-Halenda (pore size distribution) plot. The MHSF shows a uniform distribution of well-packed continuous mesopore channels that expedite the voluminous loading of receptor molecules on MHSF and the analyte diffusion to the receptor chelating sites. The DMTHBD@MHSF sensor exhibits exclusive selectivity for ultra-trace Cd 2+ , with brilliant concentration correlative color metamorphosis in ≤50 s, using a minimal sensor dose (3 mg). A distinguishable solid-state hue transition from salmon pink to intense violet is spotted in the concentration range of 1-400 microg/L, with a linear signal response between 0-150 g/L, with detection and quantification limit of 0.15 and 0.50 g/L of Cd2+, respectively. The renewable sensor demonstrates excellent stability/durability under harsh working conditions, with reliable performance even after prolonged storage. The practical applications of the proposed sensor are authenticated using diverse actual samples, with an average recovery of ≥99.43% for Cd 2+ and a relative standard deviation of ≤1.65%.
materials science, multidisciplinary,chemistry, physical,energy & fuels