Enhancing load-bearing performance of hybrid recycled aggregate concrete-filled columns using SBR, steel fibers and polypropylene fibers

Mustafa M. Khattab,Alyaa H. Mohammed,Hussain Fadhil Hussain,Wameedh Ghassan Abdul-Hussein
DOI: https://doi.org/10.1007/s41062-023-01291-7
2023-11-07
Innovative Infrastructure Solutions
Abstract:The use of recycled concrete aggregates in producing new concrete has become of greater importance due to environmental concerns. This research has presented a new way to incorporate recycled aggregates in structural columns and proposes several solutions to the downside of using recycled aggregates. An experimental test of eleven short columns subjected to axial loading up to failure was conducted. The main aim of this study is to test hybrid columns containing two kinds of concrete, normal concrete and recycled aggregates concrete. Two columns were cast as control specimens; one was cast fully from the normal concrete and the other from the recycled aggregate concrete. The remaining nine columns were cast as hybrid columns, as a reinforced normal concrete tube filled with recycled aggregate concrete, and both concretes will be cast simultaneously. The columns studied had a height of 750 mm and a diameter of 150 mm, with the RC at the core having a diameter of 75 mm and a 40 mm thickness of normal concrete surrounding it. Some of the recycled aggregate concrete-filled concrete tube columns were modified by adding Styrene butadiene rubber (SBR), steel fibers, and micro polypropylene fibers (PPF) to the mixes to improve their capacity further. All the columns were reinforced by steel (10 and 6) mm bars for the longitudinal and lateral reinforcements, respectively. Test results concluded that the behavior of hybrid reinforced concrete columns had better results than the fully recycled aggregate concrete column. The results showed that a fully casted column with recycled concrete aggregate had a significant drop in the ultimate capacity compared with the normal concrete column. The full normal and recycled aggregates columns had an ultimate capacity of 500 KN and 200 KN, respectively. While a hybrid column with no admixtures showed an improvement compared with the full recycled aggregate column, a ratio of 1.5% SBR added to the recycled aggregates concrete, recovered the loss in the ultimate strength with an ultimate capacity of 520 KN, and using steel fibers or polypropylene fibers to the outer layer with any ratio enhanced the ultimate capacity beyond the normal concrete column by improving the confinement effect. Adding steel fibers with a ratio of 1% had improved the ultimate capacity by 36% compared to the normal concrete columns and a percentage of 2% PPF had improved the ultimate capacity by 16%.
What problem does this paper attempt to address?