Comparing Contaminant Transfer Potential of Repetitive Hand-to-fomite Contacts for Gloved and Ungloved Hands Using a Fluorescent Powder

Amanda M. Wilson,Yi Liu,Kelly A. Reynolds,Catherine Noakes,Marco-Felipe King
DOI: https://doi.org/10.1016/j.ajic.2020.06.196
IF: 4.303
2020-08-01
American Journal of Infection Control
Abstract:Background Contaminant transfer has predominantly been studied under single hand-to-fomite contact scenarios as opposed to more realistic conditions that include repetitive contacts. Our study objective was to evaluate the transfer of a fluorescent powder from finger to surfaces during sequential repetitive contacts whilst investigating the effect of wearing nitrile gloves and three different surface types: plastic, glass, cloth. Methods Eighty-three participants pressed the index finger of their dominant hand into fluorescent powder. Each participant then made five sequential contacts with a surface for six trials (3 surfaces, gloved and ungloved). Loading weights were recorded on a balance during each contact. Images of the transferred powder's fluorescence were captured for the five contact areas under ultra-violet light, and transferred powder surface area and fluorescence intensity, a proxy for the amount of transferred powder, were quantified with an image analysis software: Image J. Results Participants tended to contact fomites with greater force with gloves than without. The amount of powder transferred tended to decrease over multiple contacts despite a general increase in contact force. Greater loading weight was associated with a greater area of the transferred powder. Gloved contacts tended to transfer less powder to glass surfaces, while a similar amount of powder was transferred for gloved vs. ungloved contacts with cloth or plastic. The area of powder transferred was greater for ungloved contacts than for gloved contacts for those wearing size small gloves. More similar areas of powder were transferred for gloved vs ungloved contacts for those wearing size medium or large. Conclusions This study demonstrates that surface type, glove use, and even glove size may affect the potential for contamination of surfaces. Glove use generally decreased powder transfer, especially for glass surfaces. The next steps include exploring the effects of individual differences on these patterns and utilizing these data in healthcare fomite transmission risk assessments.
infectious diseases,public, environmental & occupational health
What problem does this paper attempt to address?