THE IMPACT OF TRANSCATHETER AORTIC VALVE REPLACEMENT ON THE DYNAMICS OF ARTERIAL HYPERTENSION IN THE ELDERLY

Simina Mariana Moroz,Daniel -Dumitru Nisulescu,Mirela Baba,Ioana Mozos,Horea Feier,Daniel Florin Lighezan,Denisa Andreea Paduraru
DOI: https://doi.org/10.1097/01.hjh.0001021860.97163.a2
IF: 4.9
2024-05-01
Journal of Hypertension
Abstract:Objective: Aortic stenosis is a common heart condition characterized by the narrowing of the aortic valve, which obstructs blood flow from the heart to the rest of the body. Aortic stenosis patients undergo surgical aortic valve replacement, however, for patients at high surgical risk, transcatheter aortic valve replacement (TAVR), a minimally invasive procedure, has become an option. The present study aims to investigate the blood pressure (BP) response following transcatheter aortic valve replacement. Design and method: A retrospective analysis was conducted on a cohort of 90 patients (44 men and 46 women), who underwent TAVR between 2020-2023 in our Institute of Cardiovascular diseases. Statistical analysis was performed using MedCalc Statistical Software version 20.015 (MedCalc Software Ltd, Ostend. Belgium). BP was monitored in patients who underwent TAVR before the intervention and on the day of discharge. Clinical parameters and medical treatment were recorded during hospitalization. Patients were stratified according to their gender and post-procedural systolic and diastolic BP. Results: Mean systolic BP at admission in men was 130.56mmHg (95% C.I:125.0693 to 136.0671), versus post-procedural mean systolic BP of 124.00 mmHg (95% C.I: 118.6611 to 129.3389), p=0.0423; mean diastolic BP at admission in men was 75.29 mmHg (95% C.I: 71.5554 to 79.0355) versus post procedural mean diastolic BP of 70.34 mmHg (95% C.I: 66.8553 to 73.8265), p=0.0343. In female participants, mean systolic BP at admission was 135.19 mmHg (C.I: 127.9948 to 142.3965) and post-procedural mean systolic BP dropped to 126.34 mmHg (95% C.I: 121.4238 to 131.2719), p= 0.0094; mean diastolic BP at admission was 73.11 mmHg (95% C.I: 69.2552 to 77.0057), post-procedural mean diastolic BP was 67.73 mmHg (95% C.I: 64.1660 to 71.3123), p=0.0034. There were no statistically significant differences in the adjustment of the post-interventional medication, p=0.1823. Conclusions: TAVR is a revolutionary treatment for aortic stenosis demonstrating potential benefits in reducing blood pressure. By eliminating the obstruction caused by aortic stenosis, TAVR improves blood flow, enabling a potential decrease in blood pressure levels, regardless of gender.
peripheral vascular disease
What problem does this paper attempt to address?