Computer-aided design combined with 3D-printed osteotomy guide-assisted derotational distal femoral osteotomy for treating recurrent patellar dislocation with increased femoral anteversion angle: a retrospective study

Jiahui Chen,Jianxiong Ma,Ying Wang,Haohao Bai,Bin Lu,Xingwen Zhao,Yanfei Wu,Jing Dai,Xinlong Ma
DOI: https://doi.org/10.1007/s00264-023-05798-7
IF: 3.479
2023-04-17
International Orthopaedics
Abstract:PurposeDerotational distal femoral osteotomy (DDFO) has good clinical outcomes for the treatment of the recurrent patellar dislocation combined with increased femoral anteversion angle (FAA). Currently, there is no uniform surgical technique. The purpose of this study was to evaluate the safety and efficacy of computer-aided design (CAD) combined 3D-printed osteotomy guide-assisted DDFO for treating these patients.MethodsIn a retrospective study of 36 patients with recurrent patellar dislocation (RPD) from December 2017 to December 2020, all patients had increased FAA and underwent DDFO assisted by CAD combined with a 3D-printed osteotomy guide. Patients’ radiological parameters were used to assess the correction of increased femoral torsion and preoperative and postoperative subjective scores were recorded to evaluate the knee function. Complications were recorded to determine the safety of the surgery.ResultA total of 36 knees were included in this study, with a mean follow-up time of 32.6 ± 8.1 months. The mean age of the patients was 24.9±4.4 years and all patients experienced patellar dislocation preoperatively with a mean of 5.7±3.2 times. The patients’ femoral anteversion angle decreased from 35.03±3.05° preoperatively to 14.80±0.87°, and the TT-TG distance decreased from 20.03±1.27 mm preoperatively to 19.22±1.22 mm. The hip-knee-ankle (HKA) angle and Insall-Salvatti index were not significantly different postoperatively compared to preoperatively. The knee function scores and visual analogue scale at the last follow-up were significantly improved compared to the preoperative scores. No major complications such as redislocation, nonunion, fixation or graft failure, or infection were observed in any patients.ConclusionComputer-aided design combined with 3D-printed osteotomy guide-assisted derotational distal femoral osteotomy could correct the increased anterior femoral torsion and demonstrate good results. There were no patients experienced re-dislocation during follow-up period and the overall complication rate is low.
orthopedics
What problem does this paper attempt to address?