Faulty Feeder Detection Based on Fundamental Component Shift and Multiple-Transient-Feature Fusion in Distribution Networks

Xiangxiang Wei,Dechang Yang,Xiaowei Wang,Bin Wang,Jie Gao,Jie Wei
DOI: https://doi.org/10.1109/tsg.2020.3026390
IF: 10.275
2021-03-01
IEEE Transactions on Smart Grid
Abstract:When a single-phase-to-ground (SPG) fault occurs in a distribution network, the current is weak, and the fault conditions are complex; the existing fault detection technologies do not show reliable performance. Unlike the existing detection methods, we introduced a fundamental component shift and multiple-transient-feature fusion method in this article. To remove the fundamental component (FC) that contained in the transient zero-sequence current (TZSC), Hilbert transform was used to calculate the analytic signal of TZSC. Then, the shift factor was introduced to remove the FC such that all the transient features can be kept. Second, three typical transient features indexes were calculated. Then, the multiple evidence estimation method was used to fuse the transient features indexes. Finally, selected the feeder with the maximum fault degree as the faulty feeder. To verify the accuracy and extensive applicability of the proposed method, developed the sample radial distribution network model with different fault conditions, arc fault model, and the modified IEEE-34-node test system with power electronics generator and wind energy conversion systems, the proposed method shows good performance.
engineering, electrical & electronic
What problem does this paper attempt to address?
The paper attempts to address the issue of reliability in single-phase ground (SPG) fault detection in distribution networks. Specifically: 1. **Background and Challenges**: - Single-phase ground faults account for more than 80% of all fault types and need to be detected promptly to isolate the fault section. - With the integration of renewable energy systems such as wind and solar power, detecting SPG faults becomes particularly important to ensure power quality and protect power electronic devices. - Existing protection devices cannot accurately detect SPG faults due to the small amplitude of transient zero-sequence current (TZSC). 2. **Limitations of Existing Methods**: - **Steady-state methods**: Performance is unstable due to the influence of grid operating modes and grounding resistance. - **Transient methods**: Although modern signal processing algorithms are used to extract rich transient fault features and improve detection accuracy, these methods have some limitations, such as wavelet transform (WT) being sensitive to the choice of mother wavelet function, and Hilbert-Huang transform (HHT) having issues like mode mixing and endpoint effects. 3. **Proposed Method in the Paper**: - Introduced a fundamental component shifting and multi-transient feature fusion method. - Used Hilbert transform to calculate the analytic signal of TZSC, introduced a shifting factor to remove the fundamental component (FC), and retained all transient features. - Calculated three typical transient feature indicators: transient energy (TE), kurtosis value, and cross-correlation distance (CCD). - Used a multi-evidence estimation method to fuse transient feature indicators and selected the feeder with the highest fault degree as the fault feeder. 4. **Validation and Application**: - The proposed method's accuracy and broad applicability were validated by developing a sample radial distribution network model, an arc fault model under different fault conditions, and a modified IEEE-34 node test system (including power electronic generators and wind energy conversion systems). In summary, the paper aims to improve the reliability and accuracy of single-phase ground fault detection in distribution networks by introducing new signal processing methods and feature fusion techniques to overcome the limitations of existing methods.