A Numerical Study on the Performance of a Pumping Station with Bell-Mouth-Based Vertical Pumps during an Accidental Shutdown

Milan Sedlář,Petr Abrahámek
DOI: https://doi.org/10.3390/pr12040630
IF: 3.5
2024-03-23
Processes
Abstract:This study presents a numerical simulation of a pump's performance during a power-cut event and connected hazards resulting from the failure of non-return flap valves. The vertical mixed-flow pumps with suction bells were mounted inside the suction basins of a pumping station. Different regimes of the pump operation during the time were analyzed based on the pump's 4-quadrant characteristics and the dynamics of rotating parts in the pump, gearbox and electric engine. The resulting development of flow rates, rotor speed and forces in the course of time were used to analyze the hazards of failure of any pumping system component and the flooding of the suction object and its surroundings. The presented results show a deep insight into the flow phenomena in vertical mixed-flow pumps with suction bells during the runaway process and confirm that the developed methodology can be successfully applied to monitor the critical regimes in a pumping station in real time. The simulations were verified with some experimentally obtained data.
engineering, chemical
What problem does this paper attempt to address?
The paper primarily explores the performance of vertical mixed-flow pumps with suction bells in pump stations during unexpected power outages and investigates the associated potential risks. Specifically, the study focuses on the following aspects: 1. **Research Background**: The paper first introduces the normal operating conditions of pump stations, particularly the application scenarios of vertical mixed-flow pumps equipped with suction bells. It discusses the impact of free surface vortices on pump performance and how these issues can be avoided by increasing submergence depth or using anti-vortex devices. 2. **Research Objectives**: The main objective of the paper is to analyze the performance changes in pump stations during unexpected power outages through numerical simulation, especially in the case of non-return flap valve failure. Additionally, it aims to develop a method for real-time monitoring of critical operating conditions in pump stations. 3. **Research Methods**: The authors used Computational Fluid Dynamics (CFD) to simulate the pump's performance under various operating modes, including pump, brake, turbine, and runaway modes. Through these simulations, the researchers analyzed the changes in flow rate, rotational speed, and forces over time, and assessed the likelihood of pump system component failures and the flood risk in the suction inlet and surrounding areas. 4. **Specific Issues**: When an unexpected power outage occurs, water in the pump station will flow backward, causing a large amount of water to return from the discharge pipeline to the suction inlet, potentially leading to severe water waves and flooding. At this time, the pump's operating mode will gradually shift from pump mode to no-load turbine conditions, possibly experiencing brake mode in the process. The paper focuses on analyzing the changes in pump performance during this process, especially issues related to runaway conditions. 5. **4-Quadrant Characteristics**: To fully understand the pump's behavior under different operating modes, the study also considers the pump's 4-quadrant characteristics, which help analyze pump performance under abnormal operating conditions. In summary, the goal of this paper is to provide in-depth insights through detailed numerical simulation studies during unexpected power outages in pump stations, to better understand and predict pump behavior, thereby improving the safety and reliability of pump stations.