Whole abdominal pencil beam scanned proton FLASH increases acute lethality

Brett I. Bell,Christian Velten,Michael Pennock,Minglei Kang,Kathryn E. Tanaka,Balaji Selvaraj,Alexander Bookbinder,Wade Koba,Justin Vercellino,Jeb English,Beata Małachowska,Sanjay Pandey,Phaneendra K. Duddempudi,Yunjie Yang,Shahin Shajahan,Shaakir Hasan,J. Isabelle Choi,Charles B. Simone,Weng-Lang Yang,Wolfgang A. Tomé,Haibo Lin,Chandan Guha
DOI: https://doi.org/10.1016/j.ijrobp.2024.09.006
IF: 8.013
2024-09-19
International Journal of Radiation Oncology*Biology*Physics
Abstract:Purpose Ultra-high dose-rate FLASH radiotherapy (RT) has emerged as a modality which promises to reduce normal tissue toxicity while maintaining tumor control. Previous studies of gastrointestinal toxicity using passively scattered FLASH proton therapy (PRT) have, however, yielded mixed results, suggesting that the requirements for gastrointestinal sparing by FLASH are an open question. Furthermore, the more clinically relevant pencil beam scanned (PBS) FLASH PRT has not yet been assessed in this context, despite differences in the spatiotemporal dose-rate distributions compared to passively scattered PRT. Here, we provide the first report on the effects of PBS FLASH PRT on acute gastrointestinal injury in mice after whole abdominal irradiation. Methods and Materials Whole abdominal irradiation was performed on C57BL/6J mice using the entrance channel of the Bragg curve of a 250 MeV PBS proton beam at field-averaged dose-rates of 0.6 Gy/s for conventional (CONV) and 80-100 Gy/s for FLASH PRT. A 2D strip ionization chamber array was used to measure the dose and dose rate for each mouse. Survival was assessed at 14 Gy. Intestines were harvested and processed as Swiss rolls for analysis using a novel artificial intelligence (AI)-based crypt assay to quantify crypt regeneration 4 days post-irradiation. Results Survival was significantly reduced following 14 Gy FLASH PRT compared to CONV (P<0.001). Our AI-based crypt assays demonstrated no significant difference in intestinal crypts/cm or crypt depth between groups 4 days post-irradiation. Furthermore, we found no significant difference in EdU + cells/crypt or Olfactomedin4 + intestinal stem cells with FLASH relative to CONV PRT. Conclusions Overall, our data demonstrate significantly impaired survival following abdominal PBS FLASH PRT without apparent differences in intestinal histology 4 days post-irradiation.
oncology,radiology, nuclear medicine & medical imaging
What problem does this paper attempt to address?