Sustainable Seismic Performance of Diagrid Core-Tube Structure with Replaceable Steel Coupling Beam

Chengqing Liu,Guang Li,Bin He,Cong Zhou,Ying Ma
DOI: https://doi.org/10.3390/su16072690
IF: 3.9
2024-03-26
Sustainability
Abstract:The diagrid core-tube structure has been widely used in high-rise buildings in recent years, but there are few studies on the sustainable energy dissipation measures and seismic performance improvement of such structural systems. Because the coupling beam is the element connecting the inner tube and the outer tube in the diagrid structure, it is the first seismic defense line and an important energy-dissipation member in the seismic design of the overall structure. Therefore, this paper replaces the traditional reinforced concrete coupling beam of the inner tube of the shear wall with a replaceable energy-dissipation steel coupling beam, and the strength, stiffness, and stability of the replaceable steel coupling beam are designed to improve the sustainability of the structure. By changing the position of the replaceable coupling beam, the relative stiffness of the inner and outer tubes of the diagrid tube structure, and the plane form of the structure, the static elastoplastic analysis and seismic response energy analysis of different diagrid tube structures are carried out, and the influence of the replaceable coupling beam on the sustainable seismic performance of the diagrid tube structure is studied. The results show that the replaceable coupling beams have little effect on the ultimate bearing capacity of the structure, but the ductility and sustainability of the structure are significantly improved, and the whole building layout is the optimal layout scheme. The setting of replaceable coupling beams makes the diagrid tube structure show hysteretic energy-dissipation earlier under the action of large earthquakes, and the proportion of hysteretic energy-dissipation is greatly improved, which reduces the inter-story drift ratios and the damage degree of the diagrid columns under the action of large earthquakes. When the relative stiffness of the outer tube of the diagrid tube structure is small or the plane form of the structure is a regular quadrilateral, the application of replaceable coupling beams is more effective in improving the ductility and sustainability of the structure and reducing the damage to the diagrid column under large earthquakes.
environmental sciences,environmental studies,green & sustainable science & technology
What problem does this paper attempt to address?
The problem that this paper attempts to solve is to improve the sustainable performance of the diagrid core - tube structure under earthquake action, especially by introducing replaceable energy - dissipating steel coupling beams to improve its seismic performance and sustainability. Specifically, the paper focuses on the following aspects: 1. **Energy - dissipation Measures and Seismic Performance Improvement**: The paper points out that although the diagrid core - tube structure has been widely used in high - rise buildings, there are few studies on its sustainable energy - dissipation measures and seismic performance improvement. Therefore, the paper aims to explore how to enhance the seismic performance of this structure by designing and applying replaceable energy - dissipating steel coupling beams. 2. **The Role of Coupling Beams**: The coupling beam plays a crucial role in the diagrid core - tube structure. It connects the inner tube and the outer tube and is the first seismic defense line and an important energy - dissipating component of the structure. The paper proposes to replace the traditional reinforced concrete coupling beam with a replaceable energy - dissipating steel coupling beam to improve the overall strength, stiffness and stability of the structure. 3. **Study on the Influence of Parameters**: By changing the position of the replaceable coupling beam, the relative stiffness of the inner and outer tubes and the structural plane form, the paper conducts static elastoplastic analysis and seismic response energy analysis to study the influence of these factors on the sustainable seismic performance of the diagrid core - tube structure. 4. **Experimental Results and Conclusions**: The research shows that the replaceable coupling beam has little influence on the ultimate bearing capacity of the structure, but significantly improves the ductility and sustainability of the structure and optimizes the overall building layout plan. Under the action of a large earthquake, the setting of replaceable coupling beams makes the diagrid core - tube structure show hysteretic energy - dissipation characteristics earlier, greatly increases the proportion of hysteretic energy - dissipation, and reduces the inter - story displacement ratio and the damage degree of the diagrid columns in a large earthquake. In conclusion, through systematic research, this paper proposes a method to improve the seismic performance and sustainability of the diagrid core - tube structure by designing and applying replaceable energy - dissipating steel coupling beams, providing a valuable reference for future architectural design.