Utilizing Precursor Ion Connectivity of Different Charge States to Improve Peptide and Protein Identification in MS/MS Analysis

Lily R. Adair,Ian Jones,Rainer Cramer
DOI: https://doi.org/10.1021/acs.analchem.3c03061
IF: 7.4
2024-01-11
Analytical Chemistry
Abstract:Tandem mass spectrometry (MS/MS) has become a key method for the structural analysis of biomolecules such as peptides and proteins. A pervasive problem in MS/MS analyses, especially for top-down proteomics, is the occurrence of chimeric spectra, when two or more precursor ions are co-isolated and fragmented, thus leading to complex MS/MS spectra that are populated with fragment ions originating from different precursor ions. This type of convoluted data typically results in low sequence database...
chemistry, analytical
What problem does this paper attempt to address?
This paper attempts to solve the problem of chimeric mass spectra caused by the co - isolation of multiple precursor ions in mass spectrometry analysis, especially in top - down proteomics research. Specifically, when two or more precursor ions are simultaneously isolated and fragmented, the resulting mass spectra can be very complex, containing fragment ions from different precursor ions. Such complex mass spectrometry data usually results in lower database search scores because only a small number of the large number of fragment ions from mixed sources are derived from specific precursor ions. This not only reduces the accuracy of protein identification but also increases the false discovery rate. To solve this problem, the authors propose a new workflow to deconvolute chimeric mass spectra by exploiting the connectivity of precursor ions with different charge states, thereby increasing protein sequence coverage and database search scores. The specific methods are: 1. **Multi - charge state analysis**: Perform multiple MS/MS analyses on different charge states of the same sample. 2. **Filtering and merging**: Extract common fragment ions from each MS/MS analysis and merge them into a peak list. 3. **Noise removal**: Through the above steps, reduce chemical and biological noise and retain specific fragment ions of specific proteins. By this method, the authors have demonstrated significant improvements in experiments, especially when dealing with complex samples. The search scores have increased by 3 to 4 times, and for larger precursor ions (such as intact ubiquitin and cytochrome C), the search scores have increased by more than 6 times. This enables proteins that were previously not correctly identified or had insignificant scores to be correctly and significantly identified.