1120 Measuring Sleep Depth with Odds Ratio Product (ORP) and In-ear EEG Earbuds

Elias Meier,Mark Melnykowycz,Guy Duke,Wadda Du Toit,Kari Lambing,Federica Mozzini,Veronica Guadagni
DOI: https://doi.org/10.1093/sleep/zsae067.01120
IF: 6.313
2024-04-20
SLEEP
Abstract:Abstract Introduction Odds Ratio Product (ORP) is a highly validated measure of sleep depth and sleep-wake continuum derived from 3-second EEG epochs using spectral power analysis of the signal. It has been shown to be more sensitive than traditional sleep metrics to detect sleep quality and there is increasing scientific evidence of the ability of ORP to identify patient subgroups of sleep-wake disorders and guide personalized treatment. In-Ear EEG is an evolving method of measuring brain activity using in-ear electrodes. The current investigation assessed the signal quality of in-ear EEG data obtained from a single-channel in-ear EEG device (IDUN Guardian) alongside the frontal EEG using the Cerebra Prodigy to determine whether ORP calculation has the potential to be translated from frontal EEG to in-ear EEG. Methods 18 healthy participants (9 male) were selected ensuring diversity in age (recruited in 24-60 years old range) and sex. Participants wore the Cerebra Prodigy (with forehead electrodes), IDUN Guardian (with in-ear electrodes) while sleeping at home for 3 nights. Data from the devices was collected, synchronized, anonymized, and analyzed to assess the correlation between ORP values derived from the two systems. Results Both in-ear and frontal EEG datasets were pre-processed separately (filtered between 0.3 - 40Hz). No artifact rejection was performed. Pearson correlation coefficient of ORP values was calculated between the two systems. An average correlation of 0.35 was found for raw signals based on 3-second epochs where the in-ear EEG seemed to overestimate ORP values. This was improved (r=0.70) by averaging over 10 ORP values (30 second epoch). This is likely due to masking of variability in signals variability in summary statistics. Conclusion The results showed that single channel in-ear EEG has the potential to resolve ORP values similar to forehead EEG signals. These results suggest the need for an in-depth analysis of the spectral powers in the different frequency ranges in both systems to guide work on improving alignment between the systems. Support (if any) This research work was made possible through the Eureka Eurostars program E2634 grant and was financially supported in Switzerland by Innosuisse - Swiss Innovation Agency and in Canada by the National Research Council Canada.
neurosciences,clinical neurology
What problem does this paper attempt to address?