Transparent microfiber Fabry-Perot ultrasound sensor with needle-shaped focus for multiscale photoacoustic imaging

Jun Ma,Jing Zhao,Huiwen Chen,Li-Peng Sun,Jie Li,Bai-Ou Guan
DOI: https://doi.org/10.1016/j.pacs.2023.100482
IF: 9.656
2023-03-29
Photoacoustics
Abstract:Photoacoustic tomography emerged as a promising tool for noninvasive biomedical imaging and diseases diagnosis. However, most of the current piezoelectric ultrasound transducers suffer optical opacity and tissue-mismatched acoustic impedance, hindering the miniaturization and integration of the system for multiscale and multimodal imaging. Here, a transparent polydimethylsiloxane (PDMS) encapsulated optical microfiber ultrasound sensor was demonstrated for photoacoustic imaging with scalable spatial resolution and penetration depth. The sensor comprised a microfiber loop sandwiched by a pair of in-line Bragg gratings, which formed an ultrasound-sensitive Fabry-Perot cavity allowing free delivery of ultrasound/light beams and unique needle-shaped ultrasound focusing along the penetration depth. The sensor with a detection limit of ∼ 700 Pa and a bandwidth of ∼ 10 MHz was applied for multiscale photoacoustic imaging of mouse ear and brain vasculatures. With advantages of flexibility, optical transparence and focusing capability, the sensor offers new opportunities for developing photoacoustic/ultrasound imaging devices for biomedical and clinic applications.
engineering, biomedical,radiology, nuclear medicine & medical imaging,instruments & instrumentation
What problem does this paper attempt to address?
The main problem that this paper attempts to solve is the limitations of existing piezoelectric ultrasonic transducers in photoacoustic imaging. Specifically, traditional piezoelectric ultrasonic transducers (such as transducers based on lead zirconate titanate [PZT]) have the following problems: 1. **Optical opacity**: These transducers are unable to directly transmit light beams, resulting in increased system complexity in photoacoustic microscopes that require confocal alignment of optical and acoustic foci. 2. **Acoustic impedance mismatch**: The acoustic impedance mismatch with biological tissues limits the sensitivity of the transducers and increases the manufacturing difficulty. 3. **Difficulty in miniaturization and integration**: Due to the brittleness of the material itself and high acoustic impedance, it is difficult for the transducers to be miniaturized and integrated with other imaging modalities. To solve these problems, the authors propose a new type of transparent micro - fiber Fabry - Perot ultrasonic sensor. This sensor has the following characteristics: - **Transparency**: The micro - fiber encapsulated with polydimethylsiloxane (PDMS) ensures that the light beam can be freely transmitted, avoiding the problem of light shielding. - **Focusing ability**: The sensor can form a needle - like ultrasonic focus in the penetration depth direction, significantly improving the imaging depth and lateral resolution. - **Flexibility and stability**: The sensor has a stable structure, high mechanical strength, and can maintain its performance unchanged for several months. Through these improvements, this sensor can achieve multi - scale photoacoustic imaging, including high - resolution shallow - tissue imaging and large - depth cerebrovascular imaging, thus providing new opportunities for biomedical and clinical applications. ### Summary of mathematical formulas Some of the key formulas involved in the paper are as follows: 1. **Formula for the reflection spectrum of the Fabry - Perot cavity**: \[ R(\lambda)=\frac{(\sqrt{R_{F1}}\sqrt{R_{F2}}e^{-\alpha L})^2 + 4\sqrt{R_{F1}}\sqrt{R_{F2}}e^{-\alpha L}\sin^2(\phi)}{(1-\sqrt{R_{F1}}\sqrt{R_{F2}}e^{-\alpha L})^2 + 4\sqrt{R_{F1}}\sqrt{R_{F2}}e^{-\alpha L}\sin^2(\phi)} \] where $\alpha$ is the cavity loss, $L$ is the cavity length, $\phi=\frac{2\pi nL}{\lambda}$ is the one - way phase, and $n$ is the refractive index of the micro - fiber. 2. **Relationship between phase change and ultrasonic pressure**: \[ \frac{d\phi}{dP}\approx\frac{2\pi}{\lambda L}\left(\frac{\Delta n_{effs}}{dP}\cdot\eta_1+\frac{\Delta n_{effp}}{dP}\cdot\eta_2\right) \] where $\eta_1$ and $\eta_2$ are the energy proportions of light energy in the micro - fiber and PDMS layer respectively. These formulas describe in detail the working principle of the sensor and its response characteristics to ultrasonic waves.