Experimental Study on Rejuvenation of Aged Power Cables via Simulation Operation

Yue Xie,Yu Zhang,Yihui Lou,Jinming Zhang
DOI: https://doi.org/10.3390/en17030655
IF: 3.2
2024-01-31
Energies
Abstract:Thermal effects play a crucial role in the evolution of insulation performance in power cables during long-term operation. Before the experiments, crosslinked polyethylene (XLPE) sheets and cables were thermally aged at 105 °C for up to 180 days. Then, the heat treatments on XLPE sheets and cables were conducted in three stages. Firstly, the aged sheets were subjected to heat treatment with a temperature range of 90 to 115 °C at intervals of 5 °C, with each step lasting for 20 h. Secondly, a 7-year-serviced cable underwent simulated cable operation at the same temperature as the XLPE sheets. Thirdly, two 15- and 30-year-serviced cables were treated at temperatures ranging from 90 to 105 °C, adhering to the same intervals as the second stage. The differential scanning calorimetry (DSC), cross-linking degree, DC conduction, and breakdown strength were measured. The results show that both heat treatment methods are effective in enhancing crystallization characteristics and conductivity for XLPE sheets and aged cables, and the optimum values were achieved at decreasing temperatures as the aging period extended. Moreover, the heat treatment on retired cables yielded similar results, suggesting that a heat treatment resembling cable operation at higher temperatures would initially be beneficial for cable rejuvenation.
energy & fuels
What problem does this paper attempt to address?
### Problems Addressed by the Paper The paper primarily explores how to rejuvenate aged power cables through simulated operations. Specifically: 1. **Research Background**: - With the rapid development of cities and the increase in power demand, the stability and reliability of power transmission have become particularly important. - Cross-linked polyethylene (XLPE) has become the main insulation material in high-voltage power cables due to its excellent electrical and thermal properties. - However, during long-term operation, the performance and reliability of XLPE are affected by thermal stress. 2. **Research Objectives**: - To study the possibility of rejuvenating aged cables through thermal treatment methods that simulate cable operation processes. - To explore the impact of thermal treatment at different temperatures on the insulation performance of XLPE cables and evaluate the effectiveness of these methods in enhancing cable performance. 3. **Experimental Design**: - The experiment is divided into three stages: - Stage 1: Thermal aging treatment of new cables and cables that have been in service for 7 years. - Stage 2: Simulated operational thermal treatment of cables that have been in service for 7 years. - Stage 3: The same thermal treatment for cables that have been retired after 15 and 30 years of service. 4. **Research Results**: - Thermal treatment can effectively enhance the crystallization characteristics and conductivity of XLPE cables, with the best effects observed at lower temperatures as aging time increases. - Higher temperature thermal treatment under simulated operational conditions is beneficial for cable rejuvenation. In summary, this paper aims to optimize the performance and lifespan of power cables by experimentally studying the rejuvenation effects of thermal treatment methods on aged power cables.