Thermo‐rheological snapshot of melter feed conversion to glass

Shyla Younk,Jaime L. George,Steven A. Luksic,Jose Marcial,Derek A. Cutforth,Pavel Hrma,Pavel Ferkl,Albert A. Kruger,Richard Pokorny
DOI: https://doi.org/10.1111/jace.20208
IF: 4.186
2024-10-17
Journal of the American Ceramic Society
Abstract:Slurry feed charged into an electric melter creates a layer of reacting and melting material (termed cold cap) that floats on the surface of molten glass. The rheological behavior of heated melter feed affects the spreading of slurry at the top of the cold cap and the stability of the primary foam, affecting cold‐cap coverage and melter plenum temperatures. The apparent viscosity of a high‐alumina high‐level waste melter feed was assessed by thermomechanical analysis, high‐temperature viscometer, and the hot stage microscopy method, yielding viscosity estimates from ≈107.5 Pa s at 550°C to ≈102.5 Pa s at 1050°C. As the temperature of feed materials increased, their state changed from rigid solid to dilatant fluid, to pseudoplastic bubbly liquid with dissolving solids, to fully developed foam, and finally to Newtonian glass melt.
materials science, ceramics
What problem does this paper attempt to address?