Reliable extraction of x-ray refraction and dark-field signals with a large field of view, multi-modal scanning system at spectral energies up to 150 kVp

Thomas Partridge,Alberto Astolfo,Ian Buchanan,Gibril Kallon,Peter R T Munro,Charlotte Klara Hagen,Marco Endrizzi,David Bate,Alessandro Olivo
DOI: https://doi.org/10.1088/1361-6463/ad2096
2024-01-20
Journal of Physics D Applied Physics
Abstract:Multi-modal x-ray scanning allows the simultaneous acquisition of attenuation, refraction and ultra-small angle scattering (USAXS) or dark field images. While many examples of multi-modal x-ray scanning exist in the literature, extension to high x-ray energy, necessary to investigate dense and high-Z materials, still poses challenges. We present the investigation of attenuation, refraction and dark field images taken at 90, 120 and 150 kVp, using a scanning, large field of view multi-modal imaging system. Increases in tube voltage reduce both contrast and signal to noise but still produce satisfactory results suitable for quantitative analysis. On top of benchmarking against phantoms made of known materials, we illustrate this by scanning a 9V PP3 battery; a highly absorbing sample which causes photon starvation at lower energies.
physics, applied
What problem does this paper attempt to address?
The main problem that this paper attempts to solve is to improve the reliability and imaging quality of the multimodal X - ray imaging system under high - energy X - rays, especially for the imaging of high - density and high atomic number (high - Z) materials. Specifically, the research focuses on the ability to extract X - ray refraction and dark - field signals using a large - field - of - view multimodal scanning system at 90 kVp, 120 kVp and 150 kVp energies. The main objectives include: 1. **Evaluation of Contrast and Signal - to - Noise Ratio**: Study the multimodal image contrast and signal - to - noise ratio (SNR) at different energies to evaluate the changing trends of these parameters as the energy increases. 2. **Consistency between Theory and Experiment**: Verify the refraction signals obtained in the experiment through wave - optical simulations to ensure the reliability of the experimental results. 3. **Imaging Ability of High - Z Materials**: Demonstrate the advantages of high - energy X - rays in imaging high - Z materials by scanning a 9V PP3 battery (a highly absorptive sample), especially in overcoming the photon starvation problem. 4. **Application of Dual - Energy Scanning**: Use the medium - threshold characteristics of the detector for dual - energy scanning, explore the influence of beam hardening on the scattering signal, and verify the linear response at high energies. Through these studies, the paper aims to promote the application of multimodal X - ray imaging technology at high energies, enabling it to better serve fields such as medical imaging, security inspection, industrial testing and materials science.