Dose coefficients of mesh-type reference Korean phantoms (MRKPs) for idealized external exposure geometries of photons and electrons

Sungho Moon,Chansoo Choi,Bangho Shin,Gahee Son,Haegin Han,Hyeonil Kim,Suhyeon Kim,Jaehyo Kim,Yumin Lee,Jong Hwi Jeong,Chan Hyeong Kim,Yeon Soo Yeom
DOI: https://doi.org/10.1016/j.net.2024.10.060
IF: 2.817
2024-11-22
Nuclear Engineering and Technology
Abstract:The present study produced Korean-specific dose coefficients for idealized external exposures to photons and electrons by performing Monte Carlo dose calculations with mesh-type reference Korean phantoms (MRKPs). The Korean dose coefficients were then compared with those previously calculated using the mesh-type reference computational phantoms (MRCPs) of the International Commission on Radiological Protection (ICRP). For photons, excellent agreements in the organ/tissue dose coefficients between the Korean and ICRP phantoms were observed for the most energies except for the low energies ( ∼30 MeV, significant differences were observed in the lower energy region, especially from 0.3 to 20 MeV. For example, the gonad dose coefficient of the male MRKP was ∼57 times lower at 1.5 MeV for PA. When comparing the effective dose coefficients, the differences were generally small, i.e., generally less than 20 %, for both photons and electrons, although some exposure cases showed notable differences (e.g., 32 % at 0.03-MeV photon and 61 % at 10-MeV electron for PA).
nuclear science & technology
What problem does this paper attempt to address?